Determination of toxic glycols and alcohols in an emergency setting requires a rapid yet accurate and reliable method. To simultaneously determine diethylene glycol (DEG) along with ethylene glycol, methanol, isopropanol, acetone, and ethanol, we modified a previously developed gas chromatographic (GC) method. The system used a Hewlett-Packard 6890 GC with EPC, a Gooseneck splitless liner, and an Rtx-200 capillary column (30 m x 0.53-mm i.d., 3 mm). After serum samples were deproteinized using ultrafiltration (Millipore Ultrafree-MC), 1 mL of the protein-free filtrate was manually injected into the GC. Internal standards for alcohols (and acetone) and glycols were n-propanol and 1,3-butanediol, respectively. All compounds eluted within 3.5 min (linear temperature gradient from 40 to 260 degrees C); total run time was 6.5 min. Limit of detection and linear range for all compounds were 1 or 2.5 mg/dL and 0-500 mg/dL, respectively. In addition, there was no interference from propionic acid, propylene glycol, and 2,3-butanediol. The modifications in the equipment and temperature program allowed increased resolution and thus, detection and reliable quantitation of DEG and other common toxic glycols and alcohols of clinical interest.
منابع مشابه
Simultaneous determination of alcohols and ethylene glycol in serum by packed- or capillary-column gas chromatography.
We developed a packed-column chromatographic procedure capable of simultaneous quantitation of methanol, ethanol, isopropanol, acetone, and ethylene glycol. This method was then updated to a rapid, sensitive, wide-bore capillary method. The packed-column system uses direct injection of 1 microL of Na2WO4/H2SO4-deproteinized serum onto a 1.8 m x 2 mm (i.d.) column packed with 80/100 HayeSep R. A...
متن کاملQuantitative determination of diethylene glycol contamination in pharmaceutical products.
A simple, rapid, and reliable method was developed for the quantitative determination of diethylene glycol (DEG) in pharmaceutical products using capillary gas chromatography with flame ionization detection. The method uses ethylene glycol as internal standard and allows for the separation of propylene glycol and DEG. The assay was linear in a DEG concentration range between 1.0 and 10.00 mg/mL...
متن کاملQuantitation of diethylene glycol and its metabolites by gas chromatography mass spectrometry or ion chromatography mass spectrometry in rat and human biological samples.
The misuse of the commonly used chemical diethylene glycol (DEG) has lead to many poisonings worldwide. Methods were developed for analysis of DEG and its potential metabolites; ethylene glycol, glycolic acid, oxalic acid, diglycolic acid and hydroxyethoxy acetic acid in human urine, serum and cerebrospinal fluid samples, collected following a DEG-associated poisoning in the Republic of Panama ...
متن کاملDetermination of Icing Inhibitors (Ethylene Glycol Monomethyl Ether and Diethylene Glycol Monomethyl Ether) in Ground Water by Gas Chromatography-Mass Spectrometry
A gas chromatography/mass spectrometric assay method has been developed for the simultaneous determination of icing inhibitors, ethylene glycol monomethyl ether and diethylene glycol monomethyl ether in ground water contaminated with JP-8. Ethylene glycol monobutyl ether and ethylene glycol monoethyl ether were used as the internal standard and surrogate, respectively. 100 mL of ground water wa...
متن کاملSimultaneous determination of ethylene glycol and its major toxic metabolite, glycolic acid, in serum by gas chromatography.
We developed a gas-chromatographic procedure for the simultaneous determination of ethylene glycol (EG) and its major toxic metabolite, glycolic acid (GA), suitable for clinical use in instances of EG intoxication. After serum protein precipitation with acetonitrile (containing internal standard), the supernate is treated with 2,2-dimethoxypropane (containing dimethylformamide) to remove water,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of analytical toxicology
دوره 24 7 شماره
صفحات -
تاریخ انتشار 2000