Variable pump flow-based Doppler ultrasound method: a novel approach to the measurement of access flow in hemodialysis patients.

نویسندگان

  • Chih-Ching Lin
  • Chao-Fu Chang
  • Hong-Jen Chiou
  • Ying-Chou Sun
  • Shou-Shan Chiang
  • Ming-Wei Lin
  • Pui-Ching Lee
  • Wu-Chang Yang
چکیده

Decreasing vascular access flow (Qa) is an important predictor of future access thrombosis and malfunction for hemodialysis (HD) patients. Among all of the methods for determining Qa, the variable pump flow (VPF) Doppler method measures Qa according to the change in Doppler signal between the arterial and the venous needles under different pump flow. After this technique was combined with spectral analysis of Duplex Doppler imaging, the variable pump flow-based Doppler ultrasound method (VPFDUM) for Qa measurement was developed. This study compared the reproducibility and correlation of Qa measurements for three different methods-VPFDUM, ultrasound dilution method (UDM), and conventional Doppler ultrasound method (CDUM)-in 55 HD patients. The mean value of Qa by VPFDUM (870.8 +/- 412.0 ml/min) was close to that by UDM (868.6 +/- 417.9 ml/min) but higher than that by CDUM (either of the above values versus 685.1 +/- 303.6 ml/min; P < 0.005). The mean values of coefficient of variation were similar by VPFDUM (1.6%) and UDM (1.4%) but lower than that by CDUM (either of the above values versus 6.8%; P < 0.01). The correlation coefficient and intraclass correlation coefficient of the repeated Qa measurements by VPFDUM (0.985 and 0.993; P < 0.001) were also similar to those by UDM (0.992 and 0.995; P < 0.001) but slightly higher than those by CDUM (0.917 and 0.948; P < 0.005). Either the reproducibility of VPFDUM (r=0.98, P < 0.0001) or the correlation between VPFDUM and UDM (r=0.99, P < 0.0001) in Qa measurements is good. The unassisted patency of vascular access at 6 mo was significantly poorer in patients with Qa <500 ml/min than those with Qa >500 ml/min (13.6% versus 92.2%; P < 0.0001). In conclusion, VPFDUM is a noninvasive, accurate, and reliable procedure for Qa measurement and prediction of the prognosis of vascular access in HD patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

I-47: Doppler Ultrasound Diagnosis of Intrauterine Lesions

Background In patients with abnormal uterine bleeding, transvaginal ultrasound (TVS) is the first-line diagnostic approach to exclude endometrial pathology. If a thickened endometrium suggests endometrial pathology, sonohysterography, office hysteroscopy or dilatation and curettage are the second-line tests preferred, depending on availability and on the suspected pathology, to exclude malignan...

متن کامل

Dialysis adequacy of chronic hemodialysis patients in Zanjan-Iran, 2016

Background: Dialysis adequacy is one of the most important factors in determining the survival rate and mortality of dialysis patients. Objectives: The aim of this study was to determine the dialysis adequacy of patients undergoing chronic hemodialysis at dialysis centers located in the province of Zanjan, located in northwest Iran. Methods: This descriptive cross-sectional study was performe...

متن کامل

برآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید

  Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...

متن کامل

Ultrasound monitoring to detect access stenosis in hemodialysis patients: a systematic review.

BACKGROUND Observational studies indicate that routine measurements of access blood flow and use of Doppler ultrasound improve vascular access outcomes in hemodialysis patients, but randomized trials reached conflicting conclusions. STUDY DESIGN Systematic review and meta-analysis. SETTING & POPULATION Adult hemodialysis patients with arteriovenous accesses. SELECTION CRITERIA FOR STUDIES...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2005