Sensitive fluorescence analysis of aflatoxins using post-column UV derivatization on the Agilent 1260 Infinity LC

نویسندگان

  • Yao Xiao
  • Udo Huber
چکیده

The analysis of aflatoxins in food matrices such as grain and nuts is an important task for the food industry to ensure product safety. This Application Note shows the analysis of the four major aflatoxins after sample preparation using an immunoaffinity column, post column UV derivatization, and fluorescence detection. We show that with this method the LOD and LOQ required from the regulatory agencies can be achieved easily. This method offers a less hazardous alternative compared to the well-established, post-column electrochemical derivatization method. Authors Yao Xiao and Rong An Agilent Technologies, Inc. Beijing, China Udo Huber Agilent Technologies, Inc. Waldbronn, Germany B2

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Characteristics of the Agilent 1290 Infinity Evaporative Light Scattering Detector

The Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD) provides a wide detection range for a variety of compounds with excellent sensitivity, down to low-nanogram levels, better efficiency and greater reproducibility. It is perfect for the analysis of semivolatile and nonvolatile compounds and compounds without UV chromophores such as most amino acids and sugars. The 1290 Infini...

متن کامل

Comparison of system suitability results according to USP method USP/NF 23 for the analysis of Paracetamol (Acetaminophen) and Aspirin in pain relievers

This analysis used the system suitability test, developed on an Agilent 1200 Series LC system to test whether the Agilent 1220 and Agilent 1260 Infinity LC systems fulfilled the acceptance criteria. The chromatographic conditions of the system suitability test transferred to the Agilent 1260 and Agilent 1220 Infinity LC systems without changes. The results obtained were compared for compliance ...

متن کامل

Analysis of fat-soluble vitamins from food matrix for nutrition labeling

This Application Note shows how to carry out qualitative and quantitative analysis of fat soluble vitamins from two different food matrixes. A robust reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous determination of nine fat soluble vitamins was developed. Separation and quantification was achieved by an Agilent 1260 Infinity LC System using an Agilent Por...

متن کامل

Characterization of monoclonal antibodies on the Agilent 1260 Infinity Bio-inert Quaternary LC by Size Exclusion Chromatography using the Agilent BioSEC columns

The Agilent 1260 Bio-inert Quaternary LC System and Agilent BioSEC columns were used to investigate the purity and stability of two monoclonal antibodies (mAb): AntiFLAG and BL05. The high sensitivity of the Agilent 1260 Infinity Diode Array Detector was used to characterize these antibodies at low concentrations. The bio-inert LC system in combination with BioSEC columns resulted in the develo...

متن کامل

Superior sensitivity by seamlessly interfacing to the Agilent 6100

The applicability of Supercritical Fluid Chromatography (SFC) can be substantially enhanced by coupling SFC to Mass Spectrometric detection (MSD). In this Technical Overview, two instrument configurations are described that can be used to connect the Agilent 1260 Infinity Analytical SFC to a mass spectrometer either using an atmospheric pressure chemical ionization (APCI) or an electrospray (ES...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013