Mechanism of lumen enlargement during intracoronary stent implantation: an intravascular ultrasound study.

نویسندگان

  • J M Ahmed
  • G S Mintz
  • N J Weissman
  • A J Lansky
  • A D Pichard
  • L F Satler
  • K M Kent
چکیده

BACKGROUND Intravascular ultrasound analysis has assessed mechanisms of lumen enlargement after nonstent interventions, but not after stenting. METHODS AND RESULTS Preintervention and postintervention intravascular ultrasound was used to study 25 de novo native coronary lesions treated with single MultiLink stents without preatheroablation. External elastic membrane, lumen, and plaque and media (P&M) areas were measured every 1 mm to include the lesion and reference segments that were 5 mm proximal and distal to it. Lesion mean lumen area increased from 4.0+/-1.0 mm(2) before the intervention to 8.8+/-2.0 mm(2) after the intervention (P<0.0001) as a result of an increase in mean external elastic membrane area (14. 2+/-2.7 to 16.1+/-3.0 mm(2), P<0.0001) and a decrease in mean P&M area (10.2+/-2.2 to 7.2+/-1.8 mm(2), P<0.0001). The decrease in lesion P&M was accompanied by an increase in both proximal reference mean P&M (7.0+/-1.9 to 8.4+/-2.0 mm(2), P<0.0001) and distal reference mean P&M (5.8+/-2.1 to 7.2+/-2.1 mm(2), P<0.0001). Volumetric analysis showed an axial redistribution of plaque away from the center of the lesion toward the reference segments to increase the plaque burden in both the proximal and distal reference segments. Total (lesion plus reference) mean P&M decreased from 8. 6+/-2.1 to 7.5+/-1.8 mm(2) (P<0.0001). CONCLUSIONS The mechanisms of lumen enlargement after stenting involved (1) significant axial redistribution of plaque from the lesion into the reference segments, (2) vessel expansion, and (3) either plaque embolization or compression.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracoronary ultrasound observations during stent implantation.

T he Palmaz-Schatz stent has been used successfully to improve primary angioplasty results, to treat large coronary dissections, or to prevent impending closure of the lumen.-1-5 The determination of successful stent implantation is based on the angiographic appearance. However, angiographic projection imaging may not reveal the three-dimensional geometry that is necessary to appreciate full ex...

متن کامل

Predictors of event-free survival after repeat intracoronary procedure for in-stent restenosis; study with angiographic and intravascular ultrasound imaging.

AIMS Lumen enlargement during repeat percutaneous coronary intervention for in-stent restenosis has been shown to be the result of both stent over-expansion and decrease in neointimal tissue. How these two different mechanisms of action may influence outcome and target lesion revascularization after repeat intervention for in-stent restenosis is unclear. METHODS Intravascular ultrasound guide...

متن کامل

[Comparison between theoretical an actual intracoronary stent dimensions in non-complex lesions].

The minimum in-stent lumen diameter is a predictor of restenosis. Stent dimensions provided by manufacturers are derived from in vitro tests. The aim of this study was to compare actual stent dimensions obtained by angiography and intracoronary ultrasound with dimensions that would be expected theoretically for a given inflation pressure in a cohort of 100 non-complex lesions suitable for direc...

متن کامل

Angiographic and intravascular ultrasound predictors of in-stent restenosis.

OBJECTIVES This study was performed to determine predictors of in-stent restenosis from a high volume, single-center practice. BACKGROUND Intracoronary stents have been shown to reduce the restenosis rate as compared with balloon angioplasty, but in-stent restenosis continues to be an important clinical problem. METHODS Between April 1993 and March 1997, 1,706 patients with 2,343 lesions we...

متن کامل

Intra Vascular Ultrasound in Coronary Syndromes: an Overview

fHE CONVENTIONAL coronary angiogram provides :letails of the lumen of the coronary arteries. The mgiogram, however, does not provide information of the structure of the intima, media, and adventitia. With intracoronary ultrasound probes, it is possible to directly obtain information not only of the coronary lumen but also of the type of intraluminal structures and to differentiate cholesterol f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 102 1  شماره 

صفحات  -

تاریخ انتشار 2000