[Vessel contrast and saturation effect at three Tesla in three-dimensional time of flight magnetic resonance angiography].
نویسندگان
چکیده
The purpose of this study was to clarify the effects of the increased field strength of 1.5T vs. 3.0T on blood vessel contrast and saturation in 3D time of flight MR angiography. Vessel contrast and saturation effect were evaluated for various flow velocities and flip angles using a steady-state flow phantom. The results showed increased vessel contrast and decreased saturation of blood on 3.0T compared to 1.5T, due to the following factors: 1) sufficient saturation of stationary tissue by extended T1 relaxation time, 2) increased signal-to-noise ratio (SNR), and 3) high in-flow effect. However, the blood signal on 3.0T revealed a strong tendency to phase dispersion compared to that of 1.5T. Therefore, in order to exploit the characteristic of high field strength in 3.0T, it is suggested that adequate consideration of these factors is important in setting the image acquisition parameters.
منابع مشابه
A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla.
BACKGROUND The breathhold contrast-enhanced three-dimensional magnetic resonance angiography (MRA) using T1-weighted gradient-echo imaging sequence is the standard technique for MRA of the thorax. However, this technique is not desirable for certain patients with respiratory insufficiency, serious renal impairment, or allergy to contrast agents. The objective of this study was to optimize and e...
متن کاملImproved Cerebral Time-of-Flight Magnetic Resonance Angiography at 7 Tesla – Feasibility Study and Preliminary Results Using Optimized Venous Saturation Pulses
PURPOSE Conventional saturation pulses cannot be used for 7 Tesla ultra-high-resolution time-of-flight magnetic resonance angiography (TOF MRA) due to specific absorption rate (SAR) limitations. We overcome these limitations by utilizing low flip angle, variable rate selective excitation (VERSE) algorithm saturation pulses. MATERIAL AND METHODS Twenty-five neurosurgical patients (male n = 8, ...
متن کاملA comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced) and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms
PURPOSE To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionall...
متن کاملThree-dimensional contrast-enhanced magnetic resonance pulmonary angiography in the study of pulmonary vascular pathology.
OBJECTIVES To assess the feasibility of performing pulmonary angiography using MRI with contrast enhancement in patients with pulmonary vascular disease. METHODS We present our experience in ten individuals, two controls and eight patients who underwent the exam after injection of a gadolinium-based contrast agent on a 1 Tesla MR scanner using a time-of-flight sequence and breath-holding duri...
متن کاملAnalytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nihon Hoshasen Gijutsu Gakkai zasshi
دوره 62 10 شماره
صفحات -
تاریخ انتشار 2006