Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs

نویسندگان

  • Jinhwa Chang
  • Sujin Kim
  • Joohyun Jung
  • Heechun Lee
  • Hojung Choi
  • Dongwoo Chang
  • Youngwon Lee
  • Junghee Yoon
  • Mincheol Choi
چکیده

The objective of our study was to determine individual and global glomerular filtration rates (GFRs) using dynamic renal computed tomography (CT) in Beagle dogs. Twenty-four healthy Beagle dogs were included in the experiment. Anesthesia was induced in all dogs by using propofol and isoflurane prior to CT examination. A single slice of the kidney was sequentially scanned after a bolus intravenous injection of contrast material (iohexol, 1 mL/kg, 300 mgI/mL). Time attenuation curves were created and contrast clearance per unit volume was calculated using a Patlak plot analysis. The CT-GFR was then determined based on the conversion of contrast clearance per unit volume to contrast clearance per body weight. At the renal hilum, CT-GFR values per unit renal volume (mL/min/mL) of the right and left kidneys were 0.69 ± 0.04 and 0.57 ± 0.05, respectively. No significant differences were found between the weight-adjusted CT-GFRs in either kidney at the same renal hilum (p = 0.747). The average global GFR was 4.21 ± 0.25 mL/min/kg and the whole kidney GFR was 33.43 ± 9.20 mL/min. CT-GFR techniques could be a practical way to separately measure GFR in each kidney for clinical and research purposes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative evaluation of renal function in healthy Beagle puppies and mature dogs.

Daily urinary collection and assessment of glomerular filtration rate (GFR) and effective renal plasma flow were performed in ten 2-month-old Beagle puppies and ten 6-9 year-old Beagle dogs to identify age-associated differences in renal function. The most striking differences in puppies compared to mature dogs were a higher daily urinary volume (+65%), GFR (+87%), free water reabsorption (+159...

متن کامل

The effects of repeated intravenous iohexol administration on renal function in healthy beagles – a preliminary report

BACKGROUND Contrast induced nephrotoxicity (CIN) is a well described syndrome in humans undergoing contrast medium examinations. To date CIN has received minimal attention in the veterinary literature despite increasing use of contrast medium examinations in computed tomographic studies. METHODS This prospective study evaluated the effect of 1290 mg/kg iohexol given intravenously to 5 normal ...

متن کامل

Renal Function and Morphology in Aged Beagle Dogs Before and after Hydrocortisone Administration

Objectives of this study were to evaluate glomerular filtration rate (GFR), renal structural changes and proteinuria in aged Beagle dogs before and after hydrocortisone (HC) administration. Eleven Beagle dogs ≥10 years old were treated with either hydrocortisone (HC group, n = 6) or placebo (control group, n = 5). Urinary markers, GFR and kidney biopsies were evaluated before (T0), during (T16 ...

متن کامل

Comparison of computed tomographic and cytological results in evaluation of normal prostate, prostatitis and benign prostatic hyperplasia in dogs

Prostate gland can be structurally evaluated by computed tomography (CT) with taking advantages of tomographic feature and post-contrast parenchymal changes. The current examination initiated to determine association between computed tomographic and cytological results in evaluation of canine prostate. Thirty mature male dogs were included and under gone by both CT and fine needle sampling of p...

متن کامل

Determination of Split Renal Function Using Dynamic CT-Angiography: Preliminary Results

OBJECTIVES To determine the feasibility of a dynamic CT angiography-protocol with regard to simultaneous assessment of renal anatomy and function. METHODS 7 healthy potential kidney donors (58 ± 7 years) underwent a dynamic computed tomography angiography (CTA) using a 128-slice CT-scanner with continuous bi-directional table movement, allowing the coverage of a scan range of 18 cm within 1.7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011