Numerical simulation of left ventricular assist device implantations: comparing the ascending and the descending aorta cannulations.
نویسندگان
چکیده
In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM.
منابع مشابه
Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملTheoretical Estimation of Cannulation Methods for Left Ventricular Assist Device Support as a Bridge to Recovery
Left ventricular assist device (LVAD) support under cannulation connected from the left atrium to the aorta (LA-AA) is used as a bridge to recovery in heart failure patients because it is non-invasive to ventricular muscle. However, it has serious problems, such as valve stenosis and blood thrombosis due to the low ejection fraction of the ventricle. We theoretically estimated the effect of the...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملAxial-Flow, Transvalvular Left Ventricular Assist Device
Background. It has been suggested that left ventricular unloading at the time of reperfusion provides superior infarct salvage over reperfusion alone. The purpose of this study was to show that the Hemopump transvalvular axial-flow left ventricular assist device provides superior left ventricular unloading, ischemic zone collateral blood flow, and infarct size reduction compared with intra-aort...
متن کاملJarvik 2000: evolution of surgical implantation from conventional to minimally invasive technique.
The Jarvik 2000 is a continuous axial flow left ventricular assist device (LVAD) with an impeller type pump. It has a unique power delivery system, which is tunneled to a retroauricular skull pedestal in order to minimize driveline infections (1). Conventional implantation of the Jarvik 2000 is performed off-pump through a left postero-lateral thoracotomy, with the outflow conduit anastomosed t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical engineering & physics
دوره 35 10 شماره
صفحات -
تاریخ انتشار 2013