High-performance liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry determination of cholesterol uptake by Caco-2 cells.
نویسندگان
چکیده
A simple, sensitive and selective liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometric method (LC/APCI-MS/MS) was developed and applied to quantitative determination of uptake of cholesterol by Caco-2 human intestine cells. Caco-2 cells were cultured in medium containing cholesterol-3,4-13C2 and phytosterols from nutritional supplements after in vitro digestion. Cellular cholesterol (cholesterol-3,4-13C2) and endogenous cholesterol were extracted using methanol/chloroform (1:2, v/v) and directly analyzed using LC/APCI-MS/MS with selected reaction monitoring (SRM), using cholesterol-2,2,3,4,4,6-d6 as an internal standard. Detection and quantification limits were 2.2 and 7.2 pmol, respectively. This method provides an effective tool for rapid determination of cholesterol uptake by cells with increased selectivity and sensitivity in comparison to previously reported LC/APCI-MS analysis using selected ion monitoring (SIM).
منابع مشابه
Analysis of 9-fluorenylmethyloxycarbonyl derivatives of catecholamines by high performance liquid chromatography, liquid chromatography/mass spectrometry and tandem mass spectrometry.
9-Fluorenylmethyloxycarbonyl (FMOC) derivatives of catecholamines, including dopamine (DA; 3,4-dihydroxyphenethylamine), norepinephrine (NE; 2-amino-1-(3,4-dihydroxyphenyl)ethanol) and epinephrine (EPI; 1-phenyl-1-hydroxy-2-methylaminopropane) as well as 3, 4-dihydroxybenzylamine (DHBA) have been analyzed using high performance liquid chromatography coupled to fluorometric detection and atmosph...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 20 20 شماره
صفحات -
تاریخ انتشار 2006