Influence of the jaw tracking technique on the dose calculation accuracy of small field VMAT plans

نویسندگان

  • Ans C.C. Swinnen
  • Michel C. Öllers
  • Erik Roijen
  • Sebastiaan M. Nijsten
  • Frank Verhaegen
چکیده

PURPOSE The aim of this study was to evaluate experimentally the accuracy of the dose calculation algorithm AcurosXB in small field highly modulated Volumetric Modulated Arc Therapy (VMAT). METHOD The 1000SRS detector array inserted in the rotational Octavius 4D phantom (PTW) was used for 3D dose verification of VMAT treatments characterized by small to very small targets. Clinical treatment plans (n = 28) were recalculated on the phantom CT data set in the Eclipse TPS. All measurements were done on a Varian TrueBeamSTx, which can provide the jaw tracking technique (JTT). The effect of disabling the JTT, thereby fixing the jaws at static field size of 3 × 3 cm2 and applying the MLC to shape the smallest apertures, was investigated for static fields between 0.5 × 0.5-3 × 3 cm2 and for seven VMAT patients with small brain metastases. The dose calculation accuracy has been evaluated by comparing the measured and calculated dose outputs and dose distributions. The dosimetric agreement has been presented by a local gamma evaluation criterion of 2%/2 mm. RESULTS Regarding the clinical plans, the mean ± SD of the volumetric gamma evaluation scores considering the dose levels for evaluation of 10%, 50%, 80% and 95% are (96.0 ± 6.9)%, (95.2 ± 6.8)%, (86.7 ± 14.8)% and (56.3 ± 42.3)% respectively. For the smallest field VMAT treatments, discrepancies between calculated and measured doses up to 16% are obtained. The difference between the 1000SRS central chamber measurements compared to the calculated dose outputs for static fields 3 × 3, 2 × 2, 1 × 1 and 0.5 × 0.5 cm2 collimated with MLC whereby jaws are fixed at 3 × 3 cm2 and for static fields shaped with the collimator jaws only (MLC retracted), is on average respectively, 0.2%, 0.8%, 6.8%, 5.7% (6 MV) and 0.1%, 1.3%, 11.7%, 21.6% (10 MV). For the seven brain mets patients was found that the smaller the target volumes, the higher the improvement in agreement between measured and calculated doses after disabling the JTT. CONCLUSION Fixing the jaws at 3 × 3 cm2 and using the MLC with high positional accuracy to shape the smallest apertures in contrast to the JTT is currently found to be the most accurate treatment technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative study of identical VMAT plans with and without jaw tracking technique

The unwanted radiation transmission through the multileaf collimators could be reduced by the jaw tracking technique which is commercially available on Varian TrueBeam accelerators. On the basis of identical plans, this study aims to investigate the dosimetric impact of jaw tracking on the volumetric-modulated arc therapy (VMAT) plans. Using Eclipse treatment planning system (TPS), 40 jaw-track...

متن کامل

Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

PURPOSE To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. MATERIALS AND METHODS We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous inte...

متن کامل

Dosimetric Effect of Jaw Tracking in Volumetric-Modulated Arc Therapy

The aim of this study was to investigate the potential of jaw tracking with the volumetric-modulated arc therapy (VMAT) to reduce the normal tissue dose. Plans of nasopharynx, lung, and prostate cancers (10 plans for each) were used to perform VMAT with and without jaw tracking. The dose reduction was evaluated in terms of organ doses and integral doses. Organ-dose reduction with jaw tracking w...

متن کامل

Assessment of potential jaw‐tracking advantage using control point sequences of VMAT planning

This study aims to evaluate the potential jaw-tracking advantage using control point sequences of volume volumetric modulated arc therapy (VMAT) planning. VMAT plans for patients with prostate and head and neck (H&N) cancers were converted into new static arc (SA) plans. The SA plan consisted of a series of static fields at each control point of the VMAT plan. All other machine parameters o...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017