Hadamard Transform Time-of-Flight Mass Spectrometry
نویسندگان
چکیده
A new mode of operation of a time-of-flight mass spectrometer (TOFMS) is described and demonstrated. A continuous ion beam emerging from the ion source is accelerated and then modulated by a pseudorandom sequence of “on” and “off” pulses. The data acquisition period is set to match the period of the modulation sequence, and data are acquired synchronously with the modulation of the ion beam. The modulation sequence is deconvoluted from the data using a fast Hadamard transform (FHT) algorithm to extract the time-of-flight distribution of the ions. This multiplexing scheme increases the ion usage to ∼50% for a single detector instrument and ∼100% for a multiple detector instrument, which improves the signal level considerably over that of conventional TOFMS. The gains in signal lead to an improved signal-to-noise ratio or alternatively reduced data acquisition time, giving HT-TOFMS a major instrumental advantage over conventional TOFMS in a number of applications at little additional cost. Positive mode electrospray ionization mass spectra of tetrabutylammonium perchlorate, cesium chloride, and a protein mixture of cytochrome c and ubiquitin are presented to illustrate the method and the device.
منابع مشابه
Hadamard transform time-of-flight mass spectrometry: more signal, more of the time.
Hadamard transform time-of-flight mass spectrometry (HT-TOF MS) is a type of mass analysis that was developed to couple continuous ion sources to the inherently pulsed nature of time-of-flight measurements. Unlike conventional TOF MS, the Hadamard transform method offers a duty cycle of 50%, with the possibility of extending it to 100%. Because it is a multiplexing technique, the attainable sig...
متن کاملStopped-flow kinetic analysis using Hadamard transform time-of-flight mass spectrometry.
A home-built stopped-flow apparatus is interfaced to a Hadamard transform time-of-flight mass spectrometer, which permits study of reaction kinetics with a time between reaction initiation and observation as short as about 100 ms and a sampling rate of chemical change that can approach 1 ms. This technique is applied to the trypsin-catalyzed hydrolysis of several peptides and is validated by co...
متن کاملHadamard transform time-of-flight mass spectrometry: a high-speed detector for capillary-format separations.
This work demonstrates that with an intrinsic duty cycle of 50% and spectral storage speeds up to 277 spectra s(-1) Hadamard transform time-of-flight mass spectrometry (HT-TOFMS) is a promising detector for any capillary-format separation that can be coupled to MS by electrospray ionization. Complete resolution of the components of a nine-peptide standard was achieved by coupling pressurized-ca...
متن کاملApplication of Hadamard transform to gas chromatography/nonresonant multiphoton ionization/time-of-flight mass spectrometry.
The technique of Hadamard transform was successfully coupled with GC/nonresonant multiphoton ionization/TOFMS, for the first time. 1,4-Dichlorobenzene and the fourth harmonic generation (266 nm) of a Nd:YAG laser were employed as a model sample and an ionization laser, respectively. A Hadamard-injector coupled with a capillary-based supersonic jet nozzle (capillary-injector) was also developed ...
متن کاملEffects of modulation defects on Hadamard transform time-of-flight mass spectrometry (HT-TOFMS).
In any Hadamard multiplexing technique, discrepancies between the intended and the applied encoding sequences may reduce the intensity of real spectral features and create discrete, artificial signals. In our implementation of Hadamard transform time-of-flight mass spectrometry (HT-TOFMS), the encoding sequence is applied to the ion beam by means of an interleaved comb of wires (Bradbury-Nielso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -