A Comparative Analysis of PI Controller and Fuzzy Logic Controller for Hybrid Active Power Filter Using Dual Instantaneous Power Theory

نویسندگان

  • G. Satya Narayana
  • Narendra Kumar
چکیده

This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase systems. The Hybrid active power filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Hybrid Active Power filter is able to operate in balanced, load conditions. Classic filters may not have satisfactory performance in fast varying conditions. But auto tuned active power filter gives better results for harmonic minimization, and THD improvement. The proposed auto tuned hybrid active power filter maintains the THD well within IEEE-519 standards. The proposed methodology is extensively tested and with improved dynamic behavior of hybrid active power filter using fuzzy logic, PI controllers. The results are found to be quite satisfactory to mitigate harmonic Distortions, and improve quality. The detailed simulations are carried out on MATLAB environment to validate the performance. KeywordsFuzzy Logic Controller (FLC), Hybrid Active Power Filter (HAPF), THD, load compensation, power factor, power quality (PQ), voltage-source inverter (VSI), Proportional-Integral (PI) control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of Fuzzy Logic Based PI Controller for DFIG-based Wind Farm Aimed at Automatic Generation Control in an Interconnected Two Area Power System

This paper addresses the design procedure of a fuzzy logic-based adaptive approach for DFIGs to enhance automatic generation control (AGC) capabilities and provide better dynamic responses in multi-area power systems. In doing so, a proportional-integral (PI) controller is employed in DFIG structure to control the governor speed of wind turbine. At the first stage, the adjustable parameters of ...

متن کامل

FUZZY Logic Based Space Vector PWM Controlled Hybrid Active Power Filter for Power Conditioning

This paper investigates the comparative analysis of a Hybrid Active Power Filter with PI based SVPWM controller and fuzzy based space vector PWM controller for mitigating the harmonics, improving the power factor and increasing the distribution power of the three phase distribution system. This paper concluded that the power conditioning by fuzzy based SVPWM hybrid active power filter is superi...

متن کامل

Comparative Analysis between PI and Fuzzy Controllers for Dc Voltage Control of Unbalanced 4 Wire Shunt Active Power Filter

This research proposes a shunt active power filter (SAPF) for harmonics mitigation in order to improve power quality of the electrical network. The reference harmonic current extraction technique used was based on DQ0 power theory under unbalanced non-linear loads conditions for four wire-installed systems. The DC-link voltage plays an important role in SAPF design to guarantee both steady high...

متن کامل

Frequency Regulation of AUT Microgrid Using Modified Fuzzy PI Controller for Flywheel Energy Storage System

Usage of flywheel energy storage system (FESS) is a common method for frequency regulation due to its high power injection capacity and long life time. FESS is equipped by two back-to-back inverters including grid-side inverter and machine-side inverter. In conventional method, the machine-side inverter sets the active power and machine flux while grid-side inverter sets the reactive power and ...

متن کامل

PI, FUZZY and ANFIS Control of 3-Phase Shunt Active Power Filter

Abstract—this paper describes control of 3-phase shunt active filter by using PI, fuzzy and ANFIS controls to improve the power quality and reactive power compensation and harmonic current compensation due to nonlinear loads. The controller is capable of controlling the DC capacitor voltage capable of reference source current. Hysteresis control is used to control the current in PWM inverter. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012