Improved EIT drive patterns for a robotics sensitive skin

نویسندگان

  • David Silvera Tawil
  • David Rye
  • Mari Velonaki
چکیده

Electrical impedance tomography (EIT) is a technique used to estimate the internal conductivity of an electrically conductive body by using only measurements from its boundary. If this body is made of a thin, flexible and stretchable material that responds to touch with local changes in conductivity, it can be used to create an artificial sensitive skin. Mathematically, the EIT reconstruction problem is an ill-posed nonlinear inverse problem in which it is commonly assumed that electrodes are only located on the boundary. In a thin sensitive skin, however, electrodes can readily be located within the body. This paper compares existing drive patterns with new patterns in which a reference electrode is located inside the body. Simulation results demonstrate that placing a reference electrode in the centre of the body can improve both the resolution and robustness to noise of the reconstructed image.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Quantitative Evaluation of Drive Pattern Selection for Optimizing EIT-Based Stretchable Sensors

Electrical Impedance Tomography (EIT) is a medical imaging technique that has been recently used to realize stretchable pressure sensors. In this method, voltage measurements are taken at electrodes placed at the boundary of the sensor and are used to reconstruct an image of the applied touch pressure points. The drawback with EIT-based sensors, however, is their low spatial resolution due to t...

متن کامل

Adjacent stimulation and measurement patterns considered harmful.

We characterize the ability of electrical impedance tomography (EIT) to distinguish changes in internal conductivity distributions, and analyze it as a function of stimulation and measurement patterns. A distinguishability measure, z, is proposed which is related to the signal-to-noise ratio of a medium and to the probability of detection of conductivity changes in a region of interest. z is a ...

متن کامل

Soft Tactile Skin Using an Embedded Ionic Liquid and Tomographic Imaging

Whole-body-contact sensing will be crucial in the quest to make robots capable of safe interaction with humans. This paper describes a novel design and a fabrication method of artificial tactile sensing skin for robots. The manufacturing method described in this paper allows easy filling of a complex microchannel network with a liquid conductor (e.g., room temperature ionic liquid (RTIL)). The ...

متن کامل

Stopped light and image storage by electromagnetically induced transparency up to the regime of one minute.

The maximal storage duration is an important benchmark for memories. In quantized media, storage times are typically limited due to stochastic interactions with the environment. Also, optical memories based on electromagnetically induced transparency (EIT) suffer strongly from such decoherent effects. External magnetic control fields may reduce decoherence and increase EIT storage times conside...

متن کامل

Electrode-Skin contact impedance: In vivo measurements on an ovine model

The problem of electrical impedance between the skin and the electrode is an on-going challenge in bio-electronics. This is particularly true in the case of Electrical Impedance Tomography (EIT), which uses a large number of skin-contact electrodes and is very sensitive to noise. In the present article, contact impedance is measured and compared for a range of electrodes placed on the thorax of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009