4D‐PET data sorting into different number of phases: a NEMA IQ phantom study
نویسندگان
چکیده
This study aims at evaluating the dependence of 4D-PET data sorting on the number of phases in which the respiratory cycle can be divided. The issue is to find the best compromise to reduce the conflicting effects induced by increasing the number of phases: lesion motion on each set of images decreases, but on the other hand image noise increases. The IQ NEMA 2001 IEC body phantom was used to simulate the movement of neoplastic lesions in the thorax and abdomen, investigating the effect of target size (10-37 mm), lesion to background activity concentrations ratio (4-to-1 and 8-to-1), total acquisition time (3, 6, 12, 20 min) and number of phase partition (1, 2, 4, 6, 8, 10, 13). The phantom was moved in a cranial-caudal direction with an excursion of 25 mm and with a period of 4.0 s. Five parameters associated to lesion volume and activity concentration were considered to assess the capability of the 4D-PET technique to "freeze" the phantom motion. The results for all the parameters showed the capability of the 4D-PET acquisition technique to "freeze" the lesion motion. The division into 6 phases was found to be the best compromise between temporal resolution and image noise for the phase where the "lesions" move faster, whereas the partition into 4 phases could be used if a stable breathing phase is considered.
منابع مشابه
NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging
BACKGROUND In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2-2007 is challenging because of incomplete MR-based attenuation correction (AC) for phantom imaging. In this study, a strategy for CT-based AC of the NEMA image quality (IQ) phantom is assessed. The method is systematically evaluated in NEMA IQ phantom measurements...
متن کاملAn algorithm for automated ROI definition in water or epoxy‐filled NEMA NU‐2 image quality phantoms
Drawing regions of interest (ROIs) in positron emission tomography/computed tomography (PET/CT) scans of the National Electrical Manufacturers Association (NEMA) NU-2 Image Quality (IQ) phantom is a time-consuming process that allows for interuser variability in the measurements. In order to reduce operator effort and allow batch processing of IQ phantom images, we propose a fast, robust, autom...
متن کاملImpact of PET/CT system, reconstruction protocol, data analysis method, and repositioning on PET/CT precision: An experimental evaluation using an oncology and brain phantom
PURPOSE In longitudinal oncological and brain PET/CT studies, it is important to understand the repeatability of quantitative PET metrics in order to assess change in tracer uptake. The present studies were performed in order to assess precision as function of PET/CT system, reconstruction protocol, analysis method, scan duration (or image noise), and repositioning in the field of view. METHO...
متن کاملExperimental assessment of PET/CT repeatability
Purpose: In longitudinal oncological and brain PET/CT studies it is important to understand the repeatability of quantitative PET metrics in order to assess change in tracer uptake or binding. The present studies were performed in order to assess the aspects of PET/CT repeatability related to reconstruction settings, analysis methods, scan duration (or image noise) and position in the field of ...
متن کاملEvaluation of the combined effects of target size, respiratory motion and background activity
Gated (4D) PET/CT has the potential to greatly improve the accuracy of radiotherapy at treatment sites where internal organ motion is significant. However, the best methodology for applying 4D-PET/CT to target definition is not currently well established. With the goal of better understanding how to best apply 4D information to radiotherapy, initial studies were performed to investigate the eff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2009