MLC dosimetric characteristics for small field and IMRT applications.

نویسندگان

  • J E Bayouth
  • S M Morrill
چکیده

The objective of this work was to measure the performance characteristics of a double-focus multileaf collimator (MLC) for intensity modulated radiation therapy (IMRT), specifically the variation in penumbra and leakage for narrow fields as a function of field position over a 20x27 cm space available for segmented MLC IMRT. Measurements were made with 6 MV x rays through a MLC containing 29 leaf pairs (27 pairs of 1 cm width), and EDR2 film at 10 cm depth in solid water at 100 cm SAD. Films were digitized with 0.17 mm resolution and converted to dose. Interleaf and intraleaf transmission were measured along 11 vertical profile locations. Leaf-end transmission was measured along horizontal profiles for each of 9 different leaf abutments, traveling over a 20 cm range. In-plane penumbra measurements were made through a single leaf retracted, for 7 different leaves. Cross-plane penumbra (leaf-end) measurements were made for all 27 leaf pairs, where the 1 cm field width was placed in 11 different off-axis positions (20 cm range). Interleaf leakage (range 1.0%-1.5%), intraleaf transmission (range 0.6%-0.8%), and leaf-end transmission (range 0.8%-2.7%) were consistent for all leaf pairs at a given abutment position. The penumbra for these 1-cm-wide fields was measured to be 0.36 cm+/-0.03 cm for 99% of the measurements. In conclusion, the penumbra and leakage of the double-focus MLC were remarkably consistent for the range of leaf positions studied, producing dosimetric characteristics that are well suited for IMRT segments where opposing leaf pairs are often separated by 10 mm or less.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of physical penumbra definition in IMRT applications

Introduction: Because of small size of the beamlets in IMRT, physical penumbra is one of the important dosimetric parameters and small changes in the penumbra will have a great impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsi...

متن کامل

Dosimetric evaluation of field-in-field and sliding-window IMRT in endometrium cancer patients with a new approach for the conformity index

Background: Purpose of the study is to evaluate field-in-field (FIF) and sliding-window intensity modulated radiation therapy (SW-IMRT) treatment plans in terms of homogeneity index (HI), conformity index (CI) and normal tissue doses for organs at risk (OAR) in patients with endometrial carcinoma along with deriving a new expression for CI. Materials and Methods: Four different FIF plans with d...

متن کامل

The Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions

Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...

متن کامل

Dosimetric impact of multileaf collimator leaf width according to sophisticated grade of technique in the IMRT and VMAT planning for pituitary adenoma lesion

We analyzed the difference in the dosimetric effect between 5-mm and 2.5-mm multileaf collimator (MLC) leaf width according to the sophisticated grades of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). Nineteen patients with pituitary adenomas were selected for this study. The treatment plans were performed according to the size of the MLC (5-mm and 2.5-mm ...

متن کامل

AbstractID: 8933 Title: Performance of dual layer micro MLC versus standard single layer MLC for IMRT delivery

ID: 8933 Title: Performance of dual layer micro MLC versus standard single layer MLC for IMRT delivery Purpose To evaluate the performance characteristics of a first-of-its-kind dual layer micro multi-leaf collimator (DmMLC) and compare it dosimetrically with standard, single layer MLCs for use in intensity modulated radiation therapy (IMRT). Method and Materials The DmMLC performance was studi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 30 9  شماره 

صفحات  -

تاریخ انتشار 2003