Benchmark on Beam Interruptions in an Accelerator-driven System: Final Report on Phase II Calculations
نویسنده
چکیده
A second phase of benchmark calculations is proposed for the Beam Interruptions in a Lead-bismuthcooled and MOX-fuelled Accelerator-driven System computational problem. This second phase of calculations aims to extend the beam interruption investigation to prototypical ADSs characterised by larger fuel power densities. To this aim, the computational benchmark is no longer limited to an XADS-type system, but has been extended to include a MYRRHA ADS-type. Moreover, this second phase of calculations will investigate the impact on the fuel and coolant temperature results of different assumptions relevant to heat transfer correlations, material properties, fuel channel geometry or any other thermal-hydraulic calculation assumption. A further benchmark extension specifically devoted to irradiated fuel conditions is foreseen in the near future.
منابع مشابه
Benchmark on Beam Interruptions in an Accelerator-driven System Final Report on Phase I Calculations
This specification is proposed for a computational problem that aims to investigate the outlet core coolant temperature behaviours induced by beam interruptions of varying duration in an XADS-type system. In order to define the common application for the proposed computational benchmark, fuel channel geometry, power data, material properties, heat transfer correlations and the point kinetics ar...
متن کاملMonte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
متن کاملDevelopement a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code
Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energ...
متن کاملAccuracy Evaluation of Isogray TPS Dose Calculations in Symmetric and Asymmetric Fields of the Elekta Compact Linear Accelerator
Introduction: Radiation therapy is one of the most important methods of cancer treatment. Radiation therapy uses symmetric and asymmetric fields in which the radiation dose distribution is different. To calculate the dose distribution, computer treatment planning systems are used which must have acceptable calculations accuracy. The aim of this study was to investigate the accuracy of the dose ...
متن کاملMulti-objective Optimization of a Solar Driven Combined Power and Refrigeration System Using Two Evolutionary Algorithms Based on Exergoeconomic Concept
This paper deals with a multi-objective optimization of a novel micro solar driven combined power and ejector refrigeration system (CPER). The system combines an organic Rankine cycle (ORC) with an ejector refrigeration cycle to generate electricity and cold capacity simultaneously. Major thermodynamic parameters, namely turbine inlet temperature, turbine inlet pressure, turbine back pressure, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004