Projector calibration method based on optical coaxial camera

نویسندگان

  • Lili Xie
  • Shujun Huang
  • Zonghua Zhang
  • Feng Gao
  • Xiangqian Jiang
چکیده

The University Repository is a digital collection of the research output of the University, available on Open Access. Copyright and Moral Rights for the items on this site are retained by the individual author and/or other copyright owners. Users may access full items free of charge; copies of full text items generally can be reproduced, displayed or performed and given to third parties in any format or medium for personal research or study, educational or not­for­profit purposes without prior permission or charge, provided:

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Geometric Calibration Technique for Scalable Multi- projector Displays

We present a novel geometric calibration technique for scalable multi-projector displays. Geometric calibration plays an important role in the alignment of multi-projector systems to present a seamless tiling of the multiple projector displays. Multi-frequency Phase Measuring Profilometry technique for the geometric calibration is proposed in this work. The required framework for implementing t...

متن کامل

Uncertainty on fringe projection technique : a Monte - Carlo - based approach 1

6 Error estimation on optical full field techniques (OFFT) is millstone in the diffusion of OFFT. 7 The present work describes a generic way to estimate overall error in fringe projection, either 8 due to random sources (phase error, basically related to the quality of the camera and of the 9 fringe extraction algorithm) or the bias (calibration errors). Here, a high level calibration 10 proced...

متن کامل

Uncertainty on fringe projection technique: a Monte-Carlo-based approach

6 Error estimation on optical full field techniques (OFFT) is millstone in the diffusion of OFFT. 7 The present work describes a generic way to estimate overall error in fringe projection, either 8 due to random sources (phase error, basically related to the quality of the camera and of the 9 fringe extraction algorithm) or the bias (calibration errors). Here, a high level calibration 10 proced...

متن کامل

Direct Recovery of the Camera Internal Parameters Using Known Angles

We address the problem of direct internal calibration of a camera from a set of known angles between optical rays. A pen-size laser crosshair projector is used to generate a reference pattern whose angular features are known. Each known angle between a pair of optical rays imposes one angular constraint on the internal camera parameters. Several constraints form a system of equations, which is ...

متن کامل

Novel method for structured light system calibration

Peisen S. Huang, MEMBER SPIE State University of New York at Stony Brook Department of Mechanical Engineering Stony Brook, New York 11794 E-mail: [email protected] Abstract. System calibration, which usually involves complicated and time-consuming procedures, is crucial for any 3-D shape measurement system. In this work, a novel systematic method is proposed for accurate and quick cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016