Granisetron content of some pharmaceutical tablets was determined using a novel all-solid-state polymeric-membrane-electrode (ASS-PME) having a sensing element functioning based on an ion-exchange mechanism. The best results were observed with ASSPMEs containing 8% GST-tetrakis (p-chlorophenyl) borate as the ion-pair, 56% of dibutyl phthalate, 31% of poly(vinyl chloride), 3% of an ionic liquid and 2% of KpClTPB. The ASS element of the device was a conductive composite of graphite, MWCNTs, and an epoxy resin coated on a copper wire, and the PVC membranes were coated on the ASS. The ASS-PME showed a Nernstian response of 58.1±0.2 mV/decade over the range of 1.0×10-6 to 1.0×10-3 M. The application of the device was validated and the method was found to be applicable in the analysis of Granisetron hydrochloride in pharmaceutical formulations. KeywordsSensor, Granisetron, Polymeric membrane, All solid state, Potentiometry, Pharmaceutical formulation Analytical & Bioanalytical Electrochemistry 2017 by CEE www.abechem.com Anal. Bioanal. Electrochem., Vol. 9, No. 2, 2017, 232-244 233

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

In situ modified screen printed and carbon paste ion selective electrodes for potentiometric determination of naphazoline hydrochloride in its formulation

The construction and performance characteristics of new sensitive and selective in situ modified screen printed (ISPE) and carbon paste (ICPE) electrodes for determination of naphazoline hydrochloride (NPZ-HCl) have been developed. The electrodes under investigation show potentiometric response for NPZ-HCl in the concentration range from 7.0×10-7 to 1.0×10-2 M at 25 °C and the electrode respons...

متن کامل

Cathodic adsorptive stripping voltammetry of an anti-emetic agent Granisetron in pharmaceutical formulation and biological matrix

Granisetron showed one well-defined reduction peak at Hanging Mercury Drop Electrode (HMDE) in the potential range from -1.3 to -1.5 V due to reduction of C=N bond. Solid-phase extraction technique was employed for extraction of Granisetron from spiked human plasma. Granisetron showed peak current enhancement of 4.45% at square-wave voltammetry and 5.33% at cyclic voltammetry as compared with t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017