Factors That Affect PERCIST-Defined Test-Retest Comparability

نویسندگان

  • Hui Yuan
  • Daniel King Hung Tong
  • Varut Vardhanabhuti
  • Pek-Lan Khong
چکیده

PURPOSE The aim of this study was to evaluate the factors affecting the comparability of F-FDG PET/CT scans using the PERSIST criteria for treatment response evaluation in a clinical PET/CT unit. PATIENTS AND METHODS Patients diagnosed with esophageal cancer were assessed for treatment response by comparing 2 F-FDG PET/CT scans, at baseline (PET 1) and 1 month after the end of induction chemoradiation (PET 2). According to the PERCIST recommendations, patients with mean SUV normalized by the lean body mass within reference volume of interest that changed less than 0.3 unit and less than 20% were deemed as comparable. Absolute differences of body weight, blood glucose level, activity of F-FDG, and uptake time between the 2 scans were computed. Binary logistic regression was used to identify the predictive factors, and receiver operating characteristic curves were used for thresholds. P < 0.05 was considered statistically significant. RESULTS Sixty-nine subjects were identified. The mean (SD) values at PET 0 and PET 2 were 5.9 (1.04) mmol/L and 6.2 (1.06) mmol/L (P = 0.013), 54.6 (10.0 kg) and 53.3 (10.3 kg) (P = 0.013), 7.7 (1.3 mCi) and 7.6 (1.5 mCi) (P = 0.349), as well as 74.2 (12.4) minutes and 73.0 (12.3) minutes (P = 0.539), for blood glucose level, body weight, injected activity, and uptake time, respectively. Seventeen (24.6%) failed to match the PERCIST-defined comparability criteria. Case-based discrepancies (mean [SD]) were 0.76 (0.62) mmol/L, 3.4 (2.9) kg, 0.8 (0.7) mCi, and 11.7 (9.8) minutes for blood glucose, body weight, injected activity, and uptake time, respectively, of which only uptake time significantly affected comparability (P = 0.046; odds ratio, 1.06; 95% confidence interval, 1.00-1.12), with a limit of 2.2-minute discrepancy identified as the requirement for 100% comparability. CONCLUSIONS Uptake time had the strongest effect on PERCIST-defined comparability. Therefore, for response assessment scans, reference to initial scans for determination of optimal uptake time is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparability of Computer-based and Paper-based Versions of Writing Section of PET in Iranian EFL Context

Computer technology has provided language testing experts with opportunity to develop computerized versions of traditional paper-based language tests. New generations of TOEFL and Cambridge IELTS, BULATS, KET, PET are good examples of computer-based language tests. Since this new method of testing introduces new factors into the realm of language assessment ( e.g. modes of test delivery, famili...

متن کامل

Reliability and Validity of the Greek Migraine Disability Assessment (MIDAS) Questionnaire

BACKGROUND The Migraine Disability Assessment (MIDAS) Questionnaire is a reliable and valid instrument for migraine-related disability. Such a tool is needed to quantify migraine-related disability in the Greek population. OBJECTIVE This validation study aims to assess the test-retest reliability, internal consistency, item discriminant and convergent validity of the Greek translation of the ...

متن کامل

Longitudinal reliability of tract-based spatial statistics in diffusion tensor imaging.

Relatively little is known about reliability of longitudinal diffusion-tensor imaging (DTI) measurements despite growing interest in using DTI to track change in white matter structure. The purpose of this study is to quantify within- and between session scan-rescan reliability of DTI-derived measures that are commonly used to describe the characteristics of neural white matter in the context o...

متن کامل

Assessing bilingual and monolingual Latino students with translations of the MMPI-2: initial data.

This article presents the results of 2 studies conducted with Spanish versions of the Minnesota Multiphasic Personality Inventory-2 (MMPI-2) with Latino students. Study 1 compared the results of 2 administrations of the MMPI-2, one in English and the other in Spanish. Study 2 compared the results of administrations of 2 Spanish versions of the MMPI-2, the official Mexican adaptation and the Ver...

متن کامل

Odor and irritation thresholds for ammonia: a comparison between static and dynamic olfactometry.

Odor and lateralization (irritation) thresholds (LTs) for ammonia vapor were measured using static and dynamic olfactometry. The purpose of the study was to explore the test-retest reliability and comparability of dynamic olfactometry methodology, generally used to determine odor thresholds following European Committee for Standardization guidelines in the context of odor regulations to outside...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2015