Correlation between two methods of florbetapir PET quantitative analysis.

نویسندگان

  • Christopher Breault
  • Jonathan Piper
  • Abhinay D Joshi
  • Sara D Pirozzi
  • Aaron S Nelson
  • Ming Lu
  • Michael J Pontecorvo
  • Mark A Mintun
  • Michael D Devous
چکیده

This study evaluated performance of a commercially available standardized software program for calculation of florbetapir PET standard uptake value ratios (SUVr) in comparison with an established research method. Florbetapir PET images for 183 subjects clinically diagnosed as cognitively normal (CN), mild cognitive impairment (MCI) or probable Alzheimer's disease (AD) (45 AD, 60 MCI, and 78 CN) were evaluated using two software processing algorithms. The research method uses a single florbetapir PET template generated by averaging both amyloid positive and amyloid negative registered brains together. The commercial software simultaneously optimizes the registration between the florbetapir PET images and three templates: amyloid negative, amyloid positive, and an average. Cortical average SUVr values were calculated across six predefined anatomic regions with respect to the whole cerebellum reference region. SUVr values were well correlated between the two methods (r2 = 0.98). The relationship between the methods computed from the regression analysis is: Commercial method SUVr = (0.9757*Research SUVr) + 0.0299. A previously defined cutoff SUVr of 1.1 for distinguishing amyloid positivity by the research method corresponded to 1.1 (95% CI = 1.098, 1.11) for the commercial method. This study suggests that the commercial method is comparable to the published research method of SUVr analysis for florbetapir PET images, thus facilitating the potential use of standardized quantitative approaches to PET amyloid imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of amyloid PET ligand florbetapir F 18 binding with Aβ aggregation and neuritic plaque deposition in postmortem brain tissue.

BACKGROUND Florbetapir F 18 (F-AV-45) is a positron emission tomography imaging ligand for the detection of amyloid aggregation associated with Alzheimer disease. Earlier data showed that florbetapir F 18 binds with high affinity to β-amyloid (Aβ) plaques in human brain homogenates (Kd=3.7 nM) and has favorable imaging pharmacokinetic properties, including rapid brain penetration and washout. T...

متن کامل

A Routine PET/CT Protocol with Streamlined Calculations for Assessing Cardiac Amyloidosis Using 18F-Florbetapir

INTRODUCTION Cardiac amyloidosis is a rare condition characterized by the deposition of well-structured protein fibrils, proteoglycans, and serum proteins as amyloid. Recent work has shown that it may be possible to use (18)F-Florbetapir to image cardiac amyloidosis. Current methods for assessment include invasive biopsy techniques. This work enhances foundational work by Dorbala et al. by deve...

متن کامل

Amyloid-β assessed by florbetapir F 18 PET and 18-month cognitive decline: a multicenter study.

OBJECTIVES Florbetapir F 18 PET can image amyloid-β (Aβ) aggregates in the brains of living subjects. We prospectively evaluated the prognostic utility of detecting Aβ pathology using florbetapir PET in subjects at risk for progressive cognitive decline. METHODS A total of 151 subjects who previously participated in a multicenter florbetapir PET imaging study were recruited for longitudinal a...

متن کامل

Amyloid-β imaging with Pittsburgh compound B and florbetapir: comparing radiotracers and quantification methods.

UNLABELLED (11)C-Pittsburgh compound B ((11)C-PiB) and (18)F-florbetapir amyloid-β (Aβ) PET radioligands have had a substantial impact on Alzheimer disease research. Although there is evidence that both radioligands bind to fibrillar Aβ in the brain, direct comparisons in the same individuals have not been reported. Here, we evaluated PiB and florbetapir in a retrospective convenience sample of...

متن کامل

Impact of MR based attenuation correction on neurological PET studies

Hybrid positron emission tomography (PET) and magnetic resonance (MR) scanners have become a reality in recent years with the benefits of reduced radiation exposure, reduction of imaging time, and potential advantages in quantification. Appropriate attenuation correction remains a challenge. Biases in PET activity measurements were demonstrated using the current MR based attenuation correction ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of nuclear medicine and molecular imaging

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 2017