Follow-up versus tissue diagnosis in BI-RADS category 3 solid breast lesions at US: a cost-consequence analysis.

نویسندگان

  • Emel Alimoğlu
  • Şule Doğan Bayraktar
  • Selen Bozkurt
  • Kağan Çeken
  • Adnan Kabaalioğlu
  • Ali Apaydın
  • Hakkı Timur Sindel
چکیده

PURPOSE The aim of this study was to compare the economic effect of a proposed follow-up strategy for managing category 3 breast masses. The strategy incorporated direct tissue diagnosis at the patient's discretion for masses that had been assessed only based on ultrasonography (US) and for which mammography made no diagnostic contribution. MATERIALS AND METHODS This prospective cohort study was conducted between 2003 and 2006 and included 174 patients. We used a two-year short-term follow-up protocol composed of five steps. A biopsy was recommended for masses that were increasing in size and changing in nature. The long-term results were available at the end of 2010. The mean and total costs were calculated for the women who preferred our follow-up protocol and for those who preferred direct tissue diagnosis. The cost savings were calculated by comparing the costs of the current study protocol to the costs of two different scenarios. RESULTS Two malignancies were found among the 18 women who underwent tissue diagnosis on the recommendation of the radiologist during follow-up. Thirteen of these women underwent biopsy at the request of the patient or surgeon, and these biopsies all revealed benign tumors. The overall negative predictive value was 99.2% (95% confidence interval, 98.46%-100%). There was a statistically significant difference between the mean costs for the women who chose our follow- up regimen (147.57±106.7 TL) and those who preferred direct tissue diagnosis (426.89±149.8 TL) (P = 0.0001). The use of our follow-up protocol decreased the cost of diagnosis by 60% compared with the cost of using direct tissue diagnosis as the initial procedure. CONCLUSION Our long-term results indicate that following-up solid category 3 masses detected only by US for at least two years at short intervals is a cost-effective alternative to direct breast biopsy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast Imaging Reporting and Data System Category 3 Lesions Detected on Whole-Breast Screening Ultrasound

PURPOSE This study assessed the incidence and cancer rate of probably benign lesions detected on bilateral whole-breast screening ultrasound (US), which corresponded to US Breast Imaging Reporting and Data System (BI-RADS) category 3, and evaluated the proper management of those lesions. METHODS This study was approved by the Institutional Review Board in our institution, which waived informe...

متن کامل

Usefulness of ultrasound elastography in reducing the number of Breast Imaging Reporting and Data System category 3 lesions on ultrasonography

PURPOSE To evaluate the negative predictive value (NPV) of ultrasound (US) elastography for non-palpable Breast Imaging Reporting and Data System (BI-RADS) category 3 lesions on ultrasonography and to determine whether US elastography is helpful in reducing the number of BI-RADS category 3 lesions on ultrasonography. METHODS Two hundred seventy-six consecutive, non-palpable BI-RADS category 3...

متن کامل

Step - by - step of ultrasound - guided core - needle biopsy of the breast : review and technique *

The most consistent indications for USguided CB of breast are listed on Table 1. Patients with imaging studies revealing findings as BI-RADS category 4 (approximately 20% to 40% are malignant) or BI-RADS 5 (about 95% are malignant) must undergo biopsy. Findings classified as BI-RADS 3 present a lower risk for malignancy (< 2.0%), but such findings do require short-term follow-up. In such catego...

متن کامل

Is there any Correlation between Magnetic Resonance Imaging Features of Breast Lesions of BIRADS Category 4 with Histopathologic Results?

BACKGROUND To evaluate the correlation of magnetic resonance imaging (MRI) features of breast lesions of Breast Imaging Reporting and Database System (BI-RADS) category 4 with histopathologic results. MATERIALS AND METHODS In a prospective study between December 2013 and April 2015, patients with suspicious mammographic and/or ultrasound findings referred for Breast MRI were evaluated. Patien...

متن کامل

Reliability of Breast Ultrasound BI-RADS Final Assessment in Mammographically Negative Patients with Nipple Discharge and Radiologic Predictors of Malignancy

PURPOSE The purpose of this study was to retrospectively investigate the reliability of breast ultrasound (US) Breast Imaging Reporting and Data System (BI-RADS) final assessment in mammographically negative patients with pathologic nipple discharge, and to determine the clinical and ultrasonographic variables associated with malignancy in this group of patients. METHODS A total of 65 patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2012