Definition of the applicability domain of the Short Time Exposure (STE) test for predicting the eye irritation of chemicals.

نویسندگان

  • Kazuhiko Hayashi
  • Takayuki Abo
  • Yuko Nukada
  • Hitoshi Sakaguchi
چکیده

The Short Time Exposure (STE) test is a simple and easy-to-perform in vitro eye irritation test, that uses the viability of SIRC cells (a rabbit corneal cell line) treated for five minutes as the endpoint. In this study, our goal was to define the applicability domain of the STE test, based on the results obtained with a set of 113 substances. To achieve this goal, chemicals were selected to represent both different chemical classes and different chemical properties, as well as to cover, in a balanced manner, the categories of eye irritation potential according to the Globally Harmonised System (GHS). Accuracy analysis indicated that the rates of false negatives for organic/inorganic salts (75.0%), hydrocarbons (33.3%) and alcohols (23.5%) were high. Many of the false negative results were for solid substances. It is noteworthy that no surfactant resulted in a false negative result in the STE test. Further examination of the physical property data and performance showed a significant improvement in the predictive accuracy, when substances with vapour pressures over 6kPa were excluded from the analyses. Our results indicate that several substances - i.e. certain solids such as salts, alcohols, hydrocarbons, and volatile substances with a vapour pressure over 6kPa - do not fall within the applicability domain of the STE test. Overall, we are encouraged by the performance and improved accuracy of the STE test.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-laboratory study of short time exposure (STE) test for predicting eye irritation potential of chemicals and correspondence to globally harmonized system (GHS) classification.

Short time exposure (STE) test using rabbit corneal cell line (SIRC) cells was developed as an alternative eye irritation test. STE test uses relative viability as the endpoint after cells are exposed to the test material at constant concentrations for 5 min. In this inter-laboratory study with 3 laboratories, 44 chemicals with a wide range of classes were evaluated for the transferability, bet...

متن کامل

TiO2 Nanoparticles as a Common Component of Sunscreens: An Experimental Study of Dermal/Ocular Safety Assessment

Background: The safety evaluations of sunscreens containing Titanium Dioxide-Nanoparticles (TiO2-NPs) were done by dermal exposure, acute dermal and eye irritation/corrosion, and skin sensitization according to the guideline for Organization for Economic Co-operation and Development (OECD). OBJECTIVES: The aim of our study was the evaluation of safety and toxicity of TiO2-NPs following acute su...

متن کامل

Oecd Guidelines for the Testing of Chemicals

1. The Isolated Chicken Eye (ICE) test method was evaluated by the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), in conjunction with the European Centre for the Validation of Alternative Methods (ECVAM) and the Japanese Centre for the Validation of Alternative Methods (JaCVAM), in 2006 and 2010 (1) (2) (3). In the first evaluation, the ICE was endorsed as...

متن کامل

ارزیابی ریسک اثرات تحریکی در مواجهه شغلی با فرمالدئید در کارگران کارگاه‌های سازنده ظروف ملامین منتخب از شهر تهران

Background and aims: Melamine is a chemical widely used in the industries .It was used in the production of plastic – coated plates, glue, molding compounds and melamine dinnerware. Formaldehyde as an irritant was produced in the melamine dinnerware production and create some health problem. In this study irritant risk assessment of formaldehyde was assessed in Melamine dinnerware industr...

متن کامل

Formation interface detection using Gamma Ray log: A novel approach

There are two methods for identifying formation interface in oil wells: core analysis, which is a precise approach but costly and time consuming, and well logs analysis, which petrophysists perform, which is subjective and not completely reliable. In this paper, a novel coupled method was proposed to detect the formation interfaces using GR logs. Second approximation level (a2) of GR log gained...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Alternatives to laboratory animals : ATLA

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2013