Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function

نویسندگان

  • Karen Otte
  • Bastian Kayser
  • Sebastian Mansow-Model
  • Julius Verrel
  • Friedemann Paul
  • Alexander U Brandt
  • Tanja Schmitz-Hübsch
چکیده

BACKGROUND The introduction of low cost optical 3D motion tracking sensors provides new options for effective quantification of motor dysfunction. OBJECTIVE The present study aimed to evaluate the Kinect V2 sensor against a gold standard motion capture system with respect to accuracy of tracked landmark movements and accuracy and repeatability of derived clinical parameters. METHODS Nineteen healthy subjects were concurrently recorded with a Kinect V2 sensor and an optical motion tracking system (Vicon). Six different movement tasks were recorded with 3D full-body kinematics from both systems. Tasks included walking in different conditions, balance and adaptive postural control. After temporal and spatial alignment, agreement of movements signals was described by Pearson's correlation coefficient and signal to noise ratios per dimension. From these movement signals, 45 clinical parameters were calculated, including ranges of motions, torso sway, movement velocities and cadence. Accuracy of parameters was described as absolute agreement, consistency agreement and limits of agreement. Intra-session reliability of 3 to 5 measurement repetitions was described as repeatability coefficient and standard error of measurement for each system. RESULTS Accuracy of Kinect V2 landmark movements was moderate to excellent and depended on movement dimension, landmark location and performed task. Signal to noise ratio provided information about Kinect V2 landmark stability and indicated larger noise behaviour in feet and ankles. Most of the derived clinical parameters showed good to excellent absolute agreement (30 parameters showed ICC(3,1) > 0.7) and consistency (38 parameters showed r > 0.7) between both systems. CONCLUSION Given that this system is low-cost, portable and does not require any sensors to be attached to the body, it could provide numerous advantages when compared to established marker- or wearable sensor based system. The Kinect V2 has the potential to be used as a reliable and valid clinical measurement tool.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Persian Translation, Internal Consistency and Reliability of Wolf Motor Function Test

Background: Wolf Motor Function Test (WMFT) is used in the assessment of upper extremity motor function in stroke patients. This scale contains 15 items and assesses joint-segment movements and functional tasks. Objectives: Translation and assessment of internal consistency and reliability of the Persian version of WMFT in Iranian stroke patients. Materials and Methods: After translation ...

متن کامل

An Improved Big Bang-Big Crunch Algorithm for Estimating Three-Phase Induction Motors Efficiency

Nowadays, the most generated electrical energy is consumed by three-phase induction motors. Thus, in order to carry out preventive measurements and maintenances and eventually employing high-efficiency motors, the efficiency evaluation of induction motors is vital. In this paper, a novel and efficient method based on Improved Big Bang-Big Crunch (I-BB-BC) Algorithm is presented for efficiency e...

متن کامل

Test-Retest and Inter-Rater Reliability Study of the Schedule for Oral-Motor Assessment in Persian Children

Objectives: Reliable and valid clinical tools to screen, diagnose, and describe eating functions and dysphagia in children are highly warranted. Today most specialists are aware of the role of assessment scales in the treatment of affected individuals. However, the problem is that the clinical tools used might be nonstandard, and worldwide, there is no integrated assessment performed to assess ...

متن کامل

Validity and reliability of Kinect skeleton for measuring shoulder joint angles: a feasibility study.

OBJECTIVE To test the reliability and validity of shoulder joint angle measurements from the Microsoft Kinect™ for virtual rehabilitation. DESIGN Test-retest reliability and concurrent validity, feasibility study. SETTING Motion analysis laboratory. PARTICIPANTS A convenience sample of 10 healthy adults. METHODS Shoulder joint angle was assessed in four static poses, two trials for each...

متن کامل

Exploring accuracy of statistical characterization of gravel beds using Kinect device in the laboratory scale

Mountainous river beds-generally consist of gravel particles that the precise description of such bed is not only important hydraulically, but also it has great environmental significance. The accurate estimation of bed roughness gives us valuable information to make reliable hydraulic models of flow in river with rigorous bed form. This study discuses about the accuracy of the Kinect device in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016