Coulometric Calibration of Microvolumetric Apparatus*

نویسندگان

  • George Marinenko
  • John K. Taylor
چکیده

Coulometric tit.ratio~ provides a si~ple and accurate means to ca librate microvolumet ri c appara tus such as burets, mICroplpets, and syrInges. The apparatus to be calibrated is caused to deliver a solution of know? concentration into an electrolysis cell where it is analyzed coulometri cally. By the method descnbed, volumes ranging from 300 ILl to I ILl have been calibrated with relative standard deviation of 0.03 to 3 percent , respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The coulometric determination of glucose in human serum.

The coulometric titration method is combined with the use of an enzymatic analytic reagent for the determination of glucose in human serum. The glucose in 25 ii. of serum is determined in a protein-free filtrate (PFF) with an accuracy of ± 3% and a coefficient of variation of approximately 2%. The procedure routinely covers a concentration range of 25-250 mg/100 ml. Calibrations are linear to a...

متن کامل

Determination of Vitamin C (Ascorbic Acid) Using High Performance Liquid Chromatography Coupled with Electrochemical Detection

Vitamin C (ascorbic acid, ascorbate, AA) is a water soluble organic compound that participates in many biological processes. The main aim of this paper was to utilize two electrochemical detectors (amperometric - Coulouchem III and coulometric - CoulArray) coupled with flow injection analysis for the detection of ascorbic acid. Primarily, we optimized the experimental conditions. The optimized ...

متن کامل

Precise Coulometric Titration of Acids and Bases

Apparatus and techniques a re dc~cribed for t he t itration of ac ids a nd. bases by constantcurrent coulometry. The precision nnd accuraey of t he method aI~e JndLcated by tl traLlons of benzoic acid, potass ium acid pMhalate, adLpiC aCld, hydroc~lo l'l c aCid, ~nd sod ium eal'bonate. Standard deviations of ± 0.003 p er cent have been obtaIned which LndlCatp. that the reliabi li ty of the meth...

متن کامل

Coulometric Sensurs, the Application of a Sensor- Aci’uato3% System for Long-term Stability in Geemical S~s~~*

We present a new type of chemical transducer, the co~orn~~c sensor, This sensor is in fact an integrated sensor-actuator system that is able to measure the concentration of acids and bases by means of a coulometric titration. An ISFET is used as the sensor to monitor the pH changes induced by the actuator, which is a gold electrode that fits closely around the ISFET’s gate area. Coubmetry is an...

متن کامل

Accurate and Precise Coulometric Determination of Sulfur Dioxide in Compressed Gas Mixtures

Coulometry has been established as an important and reliable method for the determination of acidic compounds. The analytical method and simple apparatus described here arc applied to the precise and accurate determination of sulfur dioxide in nitrogen, specifically in compressed gas cylinders at nominal concentrations of 50 and 100 µmol/mol (ppm). This method is constant current coulometry whe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010