Contact activation during incubation of five different polyurethanes or glass in plasma.

نویسندگان

  • K W van der Kamp
  • K D Hauch
  • J Feijen
  • T A Horbett
چکیده

During blood-material interaction, the enzymes factor XII fragment (factor XIIf) and kallikrein are generated (contact activation). In this study, the enzymatic activities of factor XIIf and kallikrein were examined with an assay based on the conversion of tripeptide-p-nitroanilide substrate. With the use of aprotinin to inhibit kallikrein, the proteolytic activities of factor XIIf and kallikrein could be separately determined. In this in vitro study, two commercially available polyurethanes, Pellethane and Biomer; three custom synthesized polyurethanes; a biomerlike 2000 MW polytetramethyleneoxide containing polyurethane (PU-2000); an octadecyl extended (ODCE) biomer-like 2000 MW polytetramethyleneoxide containing polyurethane (PU-2000-ODCE); a hard-segment polyurethane (HS-PU); and glass (reference material) were incubated in 25% diluted plasma. In both series of experiments, glass caused the highest amidolytic activities by factor XIIf and kallikrein compared with any of the polyurethanes. In contrast, within the polyurethane group of materials, lower amidolytic activities by factor XIIf and kallikrein were measured on the custom-made polyurethanes than on the commercially available polyurethanes, although the differences among the polyurethanes were small. In addition, the influence of different ratios of material surface to the plasma incubation volume was studied. An increased ratio of surface area over plasma volume resulted in reduced contact activation, suggesting that plasma components are the limiting factor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The contact phase of coagulation in the presence of heparin.

The effect of heparin on the contact phase of coagulation has been investigated by a technique utilizing a solution of toluidine blue in calcium chloride. Heparin in a concentration of 7 units/ml. of plasma does not inhibit contact activation by glass. It is suggested that heparin does not prevent the activation of factor XII (Hageman factor) by glass or the subsequent formation of active facto...

متن کامل

Contact activation triggers stimulation of the monocyte 5-lipoxygenase pathway via plasmin.

The purpose of this study was to characterize the stimulus that activates the 5-lipoxygenase pathway in human peripheral monocytes (PM) during the process of contact activation. Incubation of PM, but not of polymorphonuclear leukocytes (PMN), in contact-activated, recalcified plasma induced a time-dependent release of leukotrienes (LT). The presence of platelets was required for the generation ...

متن کامل

In Vitro and in Vivo studies of the Effects of Cold Argon Plasma on Decreasing the Coagulation Time

Introduction Cold plasma is a self-sterilized, painless, and non-contact method in surgeries. These properties allow it to be applied to the living tissues and heat-sensitive parts. The aim of this study was to design a new cold plasma producer device and evaluate the effects of cold argon plasma on decreasing the coagulation time of blood drop in vitro and that of the injured liver blood in vi...

متن کامل

In-vitro Comparison of the Antimicrobial Properties of Glass Ionomer Cements with Zinc Phosphate Cements

     White spot lesions are observed in nearly 50% of patients undergoing orthodontic treatment. Long-lasting antibacterial properties of orthodontic cements can reduce this phenomenon. The aim of this research was to compare antimicrobial activity of three commercial glass ionomer cements with three commercial zinc phosphate cements, over time, against streptococcus mutans and candida albicans...

متن کامل

In-vitro Comparison of the Antimicrobial Properties of Glass Ionomer Cements with Zinc Phosphate Cements

     White spot lesions are observed in nearly 50% of patients undergoing orthodontic treatment. Long-lasting antibacterial properties of orthodontic cements can reduce this phenomenon. The aim of this research was to compare antimicrobial activity of three commercial glass ionomer cements with three commercial zinc phosphate cements, over time, against streptococcus mutans and candida albicans...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research

دوره 29 10  شماره 

صفحات  -

تاریخ انتشار 1995