Arterial input function measurement without blood sampling using a beta-microprobe in rats.

نویسندگان

  • Frédéric Pain
  • Philippe Lanièce
  • Roland Mastrippolito
  • Philippe Gervais
  • Philippe Hantraye
  • Laurent Besret
چکیده

UNLABELLED The evaluation of every new radiotracer involves pharmacokinetic studies on small animals to determine its biodistribution and local kinetics. To extract relevant biochemical information, time-activity curves for the regions of interest are mathematically modeled on the basis of compartmental models that require knowledge of the time course of the tracer concentration in plasma. Such a time-activity curve, usually termed input function, is determined in small animals by repeated blood sampling and subsequent counting in a well counter. The aim of the present work was to propose an alternative to blood sampling in small animals, since this procedure is labor intensive, exposes the staff to radiation, and leads to an important loss of blood, which affects hematologic parameters. METHODS Monte Carlo simulations were performed to evaluate the feasibility of measuring the arterial input function using a positron-sensitive microprobe placed in the femoral artery of a rat. The simulation results showed that a second probe inserted above the artery was necessary to allow proper subtraction of the background signal arising from tracer accumulation in surrounding tissues. This approach was then validated in vivo in 5 anesthetized rats. In a second set of experiments, on 3 rats, a third probe was used to simultaneously determine 18F-FDG accumulation in the striatum. RESULTS The high temporal resolution of the technique allowed accurate determination of the input function peak after bolus injection of 18F-FDG. Quantitative input functions were obtained after normalization of the arterial time-activity curve for a late blood sample. In the second set of experiments, compartmental modeling was achieved using either the blood samples or the microprobe data as the input function, and similar kinetic constants were found in both cases. CONCLUSION Although direct quantification proved difficult, the microprobe allowed accurate measurement of arterial input function with a high temporal resolution and no blood loss. The technique, because offering adequate sensitivity and temporal resolution for kinetic measurements of radiotracers in the blood compartment, should facilitate quantitative modeling for radiotracer studies in small animals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of a beta microprobe system to measure arterial input function in PET via an arteriovenous shunt in rats

BACKGROUND Kinetic modeling of physiological function using imaging techniques requires the accurate measurement of the time-activity curve of the tracer in plasma, known as the arterial input function (IF). The measurement of IF can be achieved through manual blood sampling, the use of small counting systems such as beta microprobes, or by derivation from PET images. Previous studies using bet...

متن کامل

Noninvasive quantification of cerebral metabolic rate for glucose in rats using 18F-FDG PET and standard input function

Measurement of arterial input function (AIF) for quantitative positron emission tomography (PET) studies is technically challenging. The present study aimed to develop a method based on a standard arterial input function (SIF) to estimate input function without blood sampling. We performed (18)F-fluolodeoxyglucose studies accompanied by continuous blood sampling for measurement of AIF in 11 rat...

متن کامل

Image-derived input function from the vena cava for 18F-FDG PET studies in rats and mice.

UNLABELLED Measurement of arterial input function is a restrictive aspect for quantitative (18)F-FDG PET studies in rodents because of their small total blood volume and the related difficulties in withdrawing blood. METHODS In the present study, we took advantage of the high spatial resolution of a recent dedicated small-animal scanner to extract the input function from the (18)F-FDG PET ima...

متن کامل

Noninvasive quantitation of cerebral blood flow using oxygen-15-water and a dual-PET system.

UNLABELLED Measurement of the arterial input function is essential for quantitative assessment of physiological function in vivo using PET. However, frequent arterial blood sampling is invasive and labor intensive. Recently, a PET system has been developed that consists of two independent PET tomographs for simultaneously scanning the brain and heart, which should avoid the need for arterial bl...

متن کامل

Metabolic liver function measured in vivo by dynamic 18F-FDGal PET/CT without arterial blood sampling

BACKGROUND Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 45 9  شماره 

صفحات  -

تاریخ انتشار 2004