Residual Stress Analysis Based on Acoustic and Optical Methods

نویسندگان

  • Sanichiro Yoshida
  • Tomohiro Sasaki
  • Masaru Usui
  • Shuichi Sakamoto
  • David Gurney
  • Ik-Keun Park
چکیده

Co-application of acoustoelasticity and optical interferometry to residual stress analysis is discussed. The underlying idea is to combine the advantages of both methods. Acoustoelasticity is capable of evaluating a residual stress absolutely but it is a single point measurement. Optical interferometry is able to measure deformation yielding two-dimensional, full-field data, but it is not suitable for absolute evaluation of residual stresses. By theoretically relating the deformation data to residual stresses, and calibrating it with absolute residual stress evaluated at a reference point, it is possible to measure residual stresses quantitatively, nondestructively and two-dimensionally. The feasibility of the idea has been tested with a butt-jointed dissimilar plate specimen. A steel plate 18.5 mm wide, 50 mm long and 3.37 mm thick is braze-jointed to a cemented carbide plate of the same dimension along the 18.5 mm-side. Acoustoelasticity evaluates the elastic modulus at reference points via acoustic velocity measurement. A tensile load is applied to the specimen at a constant pulling rate in a stress range substantially lower than the yield stress. Optical interferometry measures the resulting acceleration field. Based on the theory of harmonic oscillation, the acceleration field is correlated to compressive and tensile residual stresses qualitatively. The acoustic and optical results show reasonable agreement in the compressive and tensile residual stresses, indicating the feasibility of the idea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modelling of Resonance Frequency of MEMS Corrugated Diaphragm for Capacitive Acoustic Sensors (TECHNICAL NOTE)

In this paper, a new model for resonance frequency of clamped circular corrugated diaphragm has been presented. First, an analytical analyzes has been carried out to derive mathematic expressions for mechanical sensitivity of diaphragm with residual stress. Next by using Rayleigh's method we present mathematical model to calculate the resonance frequency of corrugated diaphragm and investigate ...

متن کامل

Characterisation of Surface Residual Stress using High Frequency Rayleigh Waves

In order to control residual stress distribution in glass, techniques based on the phenomenon of photoelasticity are efficient, though subject to the inherent limitations of all optical techniques. To mitigate these limitations, we exploit the phenomenon of acoustoelasticity to estimate residual stress distribution, using surface acoustic waves. In this study, we characterize the surface residu...

متن کامل

Determination of Residual Stress for Single and Double Autofrettage of Thick-walled FG Cylinders Subjected to Dynamic Loading

In the present article a numerical procedure is developed for dynamic analysis of single and double autofrettage of thick–walled FG cylinders under transient loading. The governing differential equations are discretized and presented in explicit Lagrangian formalism. The explicit transient solution of discrete equations are obtained on the meshed region and results for stress and strain distrib...

متن کامل

The Effect of Corrugations on Mechanical Sensitivity of Diaphragm for MEMS Capacitive Microphone

In this paper the effect of corrugated diaphragm on performance of MEMS microphone is described. The corrugated diaphragm is modeled in order to improve the sensitivity of micromachined silicon acoustic sensor. Analytical analyzes have been carried out to derive mathematic expressions for the mechanical sensitivity and displacement of corrugated diaphragm with residual stress. It is shown that ...

متن کامل

Design and Application of a Photoacoustic Sensor for Monitoring the Laser Generated Stress Waves in Optical Fiber

Measurement of stress transients generated by a 400ns pulsed HF laser in an infrared fluoride glass fiber has been made using fast time – response piezoelectric film transducer. Acoustic signals up to 12 mV with frequencies ranging in megahertz generated by 21 mJ laser pulse when passed through the fiber axis in the linear region. It is shown that useful information such as onset of non - linea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2016