Contribution of geometric design parameters to knee implant performance: Conflicting impact of conformity on kinematics and contact mechanics.
نویسندگان
چکیده
BACKGROUND Articular geometry of knee implant has a competing impact on kinematics and contact mechanics of total knee arthroplasty (TKA) such that geometry with lower contact pressure will impose more constraints on knee kinematics. The geometric parameters that may cause this competing effect have not been well understood. This study aimed to quantify the underlying relationships between implant geometry as input and its performance metrics as output. METHODS Parametric dimensions of a fixed-bearing cruciate retaining implant were randomized to generate a number of perturbed implant geometries. Performance metrics (i.e., maximum contact pressure, anterior-posterior range of motion [A-P ROM] and internal-external range of motion [I-E ROM]) of each randomized design were calculated using finite element analysis. The relative contributions of individual geometric variables to the performance metrics were then determined in terms of sensitivity indices (SI). RESULTS The femoral and tibial distal or posterior radii and femoral frontal radius are the key parameters. In the sagittal plane, distal curvature of the femoral and tibial influenced both contact pressure, i.e., SI=0.57; SI=0.65, and A-P ROM, i.e., SI=0.58; SI=0.6, respectively. However, posterior curvature of the femoral and tibial implants had a smaller impact on the contact pressure, i.e., SI=0.31; SI=0.23 and a higher impact on the I-E ROM, i.e., SI=0.72; SI=0.58. It is noteworthy that in the frontal plane, frontal radius of the femoral implant impacted both contact pressure (SI=0.38) and I-E ROM (SI=0.35). CONCLUSION Findings of this study highlighted how changes in the conformity of the femoral and tibial can impact the performance metrics.
منابع مشابه
Posterior stabilized versus cruciate retaining total knee arthroplasty designs: conformity affects the performance reliability of the design over the patient population.
Commercially available fixed bearing knee prostheses are mainly divided into two groups: posterior stabilized (PS) versus cruciate retaining (CR). Despite the widespread comparative studies, the debate continues regarding the superiority of one type over the other. This study used a combined finite element (FE) simulation and principal component analysis (PCA) to evaluate "reliability" and "sen...
متن کاملEffect of different walking speed on the gait kinematics of individuals with knee varus
The purpose of current study was to investigate the spatio-temporal gait parameters and knee varus angle during walking at different speeds in young with knee varus. 18 subjects with varus deformity classified at grade 3 of bowleg and 17 healthy subjects, volunteered to participate in this study. The following variables include stance, swing, double support and cycle time, cadence, stride le...
متن کاملInfluence of conformity on the wear of total knee replacement: An experimental study
Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this s...
متن کاملContact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.
Diameter and diametral clearance of the bearing surfaces of metal-on-metal hip implants and structural supports have been recognised as key factors to reduce the dry contact and hydrodynamic pressures and improve lubrication performance. On the other hand, application of aspherical bearing surfaces can also significantly affect the contact mechanics and lubrication performance by changing the r...
متن کاملThe Influence of Implant Design
Traditional knee replacement designs utilize multiple discrete radii to define the sagittal plane curvature of the femoral component (Fig. 1). This geometry was derived to replicate the function of the natural knee joint. The broader distal radius articulating against a relatively congruent tibial insert provides increased constraint and reduced contact stress in the range of flexion used for h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Knee
دوره 22 3 شماره
صفحات -
تاریخ انتشار 2015