This paper present an evaluation of overvoltages in low-voltage LV installation in buildings in cases of direct lightning strikes to overhead medium voltage lines. The study considered typical power systems with lowand medium voltage surge arresters. The calculation have been performed using the EMPTATP
منابع مشابه
Application of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes
In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...
متن کاملTransient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA
In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...
متن کاملLightning Performance of High Voltage Transmission Lines Protected by Surge Arresters: a Simulation for the Hellenic Transmission Network
Lightning strikes to overhead transmission lines are a usual reason for unscheduled supply interruptions in the modern power systems. In an effort to maintain failure rates in a low level, providing high power quality and avoiding damages and disturbances, plenty of lightning performance estimation studies have been conducted and several design methodologies have been proposed. The protection o...
متن کاملThe influence of lightning induced voltage on the distribution power line polymer insulators
Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line p...
متن کاملLightning Protection of Overhead Power Distribution Lines
Distribution lines are often located in areas with high ground flash densities, being therefore subject to lightning-caused power interruptions. This paper presents an overview of the various types of lightning overvoltages that can arise on overhead power distribution networks, as well as typical voltage waveforms. The effectivenesses of the most important methods for mitigating such overvolta...