PURPOSE Chest compressions are often performed at a variable rate during cardiopulmonary resuscitation (CPR). The effect of compression rate on other chest compression quality variables (compression depth, duty-cycle, leaning, performance decay over time) is unknown. This randomised controlled cross-over manikin study examined the effect of different compression rates on the other chest compression quality variables. METHODS Twenty healthcare professionals performed 2 min of continuous compressions on an instrumented manikin at rates of 80, 100, 120, 140 and 160 min(-1) in a random order. An electronic metronome was used to guide compression rate. Compression data were analysed by repeated measures ANOVA and are presented as mean (SD). Non-parametric data was analysed by Friedman test. RESULTS At faster compression rates there were significant improvements in the number of compressions delivered (160(2) at 80 min(-1) vs. 312(13) compressions at 160 min(-1), P<0.001); and compression duty-cycle (43(6)% at 80 min(-1) vs. 50(7)% at 160 min(-1), P<0.001). This was at the cost of a significant reduction in compression depth (39.5(10)mm at 80 min(-1) vs. 34.5(11)mm at 160 min(-1), P<0.001); and earlier decay in compression quality (median decay point 120 s at 80 min(-1) vs. 40s at 160 min(-1), P<0.001). Additionally not all participants achieved the target rate (100% at 80 min(-1) vs. 70% at 160 min(-1)). Rates above 120 min(-1) had the greatest impact on reducing chest compression quality. CONCLUSIONS For Guidelines 2005 trained rescuers, a chest compression rate of 100-120 min(-1) for 2 min is feasible whilst maintaining adequate chest compression quality in terms of depth, duty-cycle, leaning, and decay in compression performance. Further studies are needed to assess the impact of the Guidelines 2010 recommendation for deeper and faster chest compressions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An appropriate compression pace is important for securing the quality of hands-only CPR--a manikin study.

It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compression...

متن کامل

Comparison of the quality of chest compressions on a dressed versus an undressed manikin: A controlled, randomised, cross-over simulation study

BACKGROUND Undressing the chest of a cardiac arrest victim may delay the initiation of chest compressions. Furthermore, expecting laypeople to undress the chest may increase bystander reluctance to perform cardiopulmonary resuscitation (CPR). Both of these factors might conceivably decrease survival following cardiac arrest. Therefore, the aim of this study was to examine if the presence or abs...

متن کامل

Minute ventilation at different compression to ventilation ratios, different ventilation rates, and continuous chest compressions with asynchronous ventilation in a newborn manikin

BACKGROUND In newborn resuscitation the recommended rate of chest compressions should be 90 per minute and 30 ventilations should be delivered each minute, aiming at achieving a total of 120 events per minute. However, this recommendation is based on physiological plausibility and consensus rather than scientific evidence. With focus on minute ventilation (Mv), we aimed to compare today's stand...

متن کامل

Feedback on the Rate and Depth of Chest Compressions during Cardiopulmonary Resuscitation Using Only Accelerometers

BACKGROUND Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to ob...

متن کامل

A randomized cross-over study of the quality of cardiopulmonary resuscitation among females performing 30:2 and hands-only cardiopulmonary resuscitation

BACKGROUND Hands-Only cardiopulmonary resuscitation (CPR) is recommended for use on adult victims of witnessed out-of-hospital (OOH) sudden cardiac arrest or in instances where rescuers cannot perform ventilations while maintaining minimally interrupted quality compressions. Promotion of Hands-Only CPR should improve the incidence of bystander CPR and, subsequently, survival from OOH cardiac ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Resuscitation

دوره 83 3  شماره 

صفحات  -

تاریخ انتشار 2012