Cell lysis inside the capillary facilitated by transverse diffusion of laminar flow profiles (TDLFP).

نویسندگان

  • Maxim V Berezovski
  • Tak W Mak
  • Sergey N Krylov
چکیده

Chemical cytometry studies the molecular composition of individual cells by means of capillary electrophoresis or capillary chromatography. In one of its realizations an intact cell is injected inside the capillary, the plasma membrane is disrupted to release the cellular contents into the separation buffer, and, finally, the molecules of interest are separated and detected. The solubilization of the plasma membrane with a surfactant is a simple and efficient way of achieving cell lysis inside the capillary. To facilitate cell lysis by a surfactant the cell has to be contacted with the surfactant inside the capillary. We recently introduced a generic method for mixing solutions inside the capillary termed transverse diffusion of laminar flow profiles (TDLFP). In this work, we propose that TDLFP can facilitate efficient cell lysis inside the capillary. Conceptually, a short plug of the surfactant is injected by pressure prior to cell injection. The cell is then injected by pressure within a plug of the physiological buffer. Due to the parabolic profiles of pressure-driven laminar flows the interface between the plug of the surfactant and that of the physiological buffer is predominantly longitudinal. Transverse diffusion mixes the surfactant with the physiological buffer, which leads to surfactant's contact with the cell and subsequent cell lysis. Here, we demonstrate that the proposed concept is valid. TDLFP-facilitated cell lysis by a short plug of the surfactant allows us to exclude the surfactant from the run buffer, and, hence, facilitates modes of separation, which are incompatible with the surfactant's presence in the run buffer. In addition to cell lysis, TDLFP will be used to mix the cellular components with labeling reactants, affinity probes, inhibitors, etc. We foresee that the generic nature and enabling capabilities of TDLFP will speed up the maturation of chemical cytometry into a practical bioanalytical tool.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mathematical model for mixing reactants in a capillary microreactor by transverse diffusion of laminar flow profiles.

Transverse diffusion of laminar flow profiles (TDLFP) was recently suggested as a generic approach for mixing reactants inside a capillary microreactor. Conceptually, solutions of reactants are injected inside the capillary by high pressure as a series of consecutive plugs. Because of the laminar nature of the flow inside the capillary, the nondiffused plugs have parabolic profiles with predomi...

متن کامل

Transverse diffusion of laminar flow profiles to produce capillary nanoreactors.

We introduce transverse diffusion of laminar flow profiles (TDLFP), the first generic method for mixing two or more reactants inside capillaries. Conceptually, solutions of reactants are injected inside the capillary by pressure as a series of consecutive plugs. Due to the laminar nature of flow inside the capillary, the nondiffused plugs have parabolic profiles with predominantly longitudinal ...

متن کامل

New in-capillary electrophoretic kinase assays to evaluate inhibitors of the PI3k/Akt/mTOR signaling pathway.

Human kinases are one of the most promising targets for cancer therapy. Methods able to measure the effects of drugs on these cell agents remain crucial for biologists and medicinal chemists. The current work therefore sought to develop an in-capillary enzymatic assay based on capillary electrophoresis (CE) to evaluate the inhibition of phosphatidylinositol-3-kinase (PI3K), protein kinase B (Ak...

متن کامل

On-line capillary electrophoresis-based enzymatic methodology for the study of polymer-drug conjugates.

This work aims at studying the potentialities of an on-line capillary electrophoresis (CE)-based digestion methodology for evaluating polymer-drug conjugates degradability in the presence of free trypsin (in-solution digestion). A sandwich plugs injection scheme with transverse diffusion of laminar profile (TDLFP) mode was used to achieve on-line digestions. Electrophoretic separation condition...

متن کامل

Mathematical Analysis of MHD Flow of Blood in Very Narrow Capillaries (RESEARCH NOTE)

A mathematical model for blood flow in narrow capillaries under the effect of transverse magnetic field has been investigated. It is assumed that there is a lubricating layer between red blood cells and tube wall. The transient flow of the fit red blood cell surrounded by plasma annulus in the narrow capillary is considered. The analysis of fluid flow between red cell and tube wall, when the ce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 387 1  شماره 

صفحات  -

تاریخ انتشار 2007