The Design and Evaluation of a Low-volume Total Suspended Particulate Sampler

نویسندگان

  • John D. Wanjura
  • Calvin B. Parnell
  • Bryan W. Shaw
  • Ronald E. Lacey
چکیده

The regulation of particulate matter (PM) emitted by agricultural sources (cotton gins, feed mills, concentrated animal feeding operations (CAFOs) is based upon downwind concentrations of particulate matter less than 10 and 2.5 micrometers (μm) (PM10 and PM2.5) aerodynamic equivalent diameter (AED). Both PM10 and PM2.5 samplers operate by pre-separating PM larger than the size of interest (10 and 2.5 μm) prior to capturing the PM on the filter. It has been shown that Federal Reference Method (FRM) PM10 and PM2.5 samplers have concentration measurement errors (Buser et al, 2001, 2002) when sampling PM in ambient air having mass median diameters (MMD) larger than the size of interest. It has also been demonstrated that most PM from agricultural sources typically have particle size distributions with MMDs larger than 10 μm (AED). The PM10 concentration measurement error can be as much as 343% for ambient PM with an MMD=20 μm. These errors are a consequence of the PM10 pre-separator allowing a larger mass of PM greater than 10 μm to penetrate to the filter than the mass of PM less than 10 μm captured by the pre-separator. The mass of the particles greater than 10μm that are allowed to penetrate to the filter, introduce a substantial error in the calculated concentration of PM10. Pargmann et al (2001) reported that sampling PM larger than 2.5 μm (AED) resulted in a shift in the cut-point of the pre-separator. If this is true for all PM10 and PM2.5, samplers, the resulting errors in measurements of ambient concentrations could be even larger than those reported by Buser. One solution to this problem is to measure the concentration of total suspended particulate matter (TSP) and calculate the concentration of PM10 by determining the mass fraction of PM less than size of interest from the particle size distribution (PSD). The “standard” high volume (TSP) sampler operates at a volume rate-of-flow in excess of 40 cubic feet per minute (cfm) (EPA, 1987b). Most of the current PM10 and PM2.5 samplers operate at one cubic meter per hour (cmh). (1 cmh = 0.589 cfm.) McFarland (1983) reported that TSP samplers have a “cut-point” of a nominal 45 μm (AED). EPA specifies the engineering design parameters for TSP samplers in 40CFR Part 50 (1987b). This paper reports the engineering design and evaluation of a low-volume (0.589 cfm) TSP sampler (TSPLV). The results suggest that this new TSPLV may be more robust and more accurate that the “standard” high volume (TSP) sampler.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Polycyclic Aromatic Hydrocarbons in Ambient Urban Air

Polycyclic aromatic hydrocarbons (PAHS) have been determined in the atmosphere of Isfahan, Iran. Airborne particulate matter was sampled using a high-volume air sampler at roof-top level (~6m). Extraction of PAHS from airborne particulate matter has been performed using SFE system and the relationship between the extraction temperature and the recovery of PAHS</su...

متن کامل

Instrumental neutron activation analysis of air suspended particles in Rasht city, Iran

Background: In addition to gas pollutants, many chemicals and air pollutants are in the form of particulate matter. Particulate matter consists of a complex mixture of variable sized particles and physicochemical composition. These particles mainly contain minerals including Fe, Al, Ca, K, Cu, Ti, Mn, Ni, V and their size, chemical composition and concentration are important to assess ...

متن کامل

Indoor air pollution and asthma in children at Delhi, India.

INTRODUCTION Several studies in developed countries have shown association between indoor air pollution and asthma in children. The present research was undertaken to study this association at Delhi, India. MATERIAL AND METHODS This study took place at Delhi, capital of India. Eight locations based on the source of pollution such as industrial, residential and villages were included. Recordin...

متن کامل

An Approach to the Design of a Particulate System for Oral Protein Delivery .II. Preparation and Stability Study of rhGH-Loaded Microspheres in Simulated Gastrointestinal Fluids

The delivery of therapeutic proteins has gained momentum with development of biotechnology. However, large molecular weight, hydrophilic nature and susceptibility to harsh environment of gastrointestinal tract (GIT) resulted in low absorption. The main objective of this work was the design of a particulate system for oral delivery of recombinant human growth hormone (rhGH) on the basis of parti...

متن کامل

Design of an Inhalation Chamber to Expose Laboratory Animals with Suspended Particulate Matter by Numerical Simulation Method

Introduction: Usually, in the toxicological studies of airborne particulate pollutants, inhalation exposure chambers are used for providing and distributing the test atmosphere uniformly and stability in the respiratory zone of laboratory animals. The purpose of this study was to design, evaluate and optimize a whole-body exposure chamber, specifically for small laboratory animals exposed to pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003