Improved detection of intraventricular cysticercal cysts with the use of three-dimensional constructive interference in steady state MR sequences.

نویسندگان

  • S S Govindappa
  • J P Narayanan
  • V M Krishnamoorthy
  • C H Shastry
  • A Balasubramaniam
  • S S Krishna
چکیده

BACKGROUND AND PURPOSE Before the advent of MR imaging, intraventricular cysts were difficult to diagnose noninvasively. Among the invasive procedures used were contrast ventriculography and CT ventriculography. MR imaging, with its multiplanar imaging capabilities, excellent depiction of tissue contrast, and versatile parameters, is an important tool in the assessment of intraventricular cystic lesions. We investigated the role of three-dimensional constructive interference in steady state (3D-CISS) MR sequences in the evaluation of intraventricular cysticercal cysts. METHODS The study group comprised 11 patients with intraventricular cysticercal cysts. MR studies included spin-echo (SE) T1-weighted, turbo-SE T2-weighted, and 3D-CISS sequences. All images were obtained on a superconducting 1.5-T MR unit. The routine and 3D-CISS sequences were reviewed and interpreted separately by two neuroradiologists. RESULTS All patients underwent surgery for excision of intraventricular cysticercal cysts. Eight patients had cysts in the fourth ventricle, two in the lateral ventricle, and one in the third ventricle. SE T1-weighted images showed the cystic wall in nine cases, the scolex in four, and the cystic fluid in two. Turbo-SE T2-weighted images showed the cystic wall and scolex in three and four cases, respectively. The routine sequences did not show the scolex, cystic wall, or cystic fluid together in any of the 11 patients. 3D-CISS images showed the scolex in all 11 patients and the cystic wall and cystic fluid in eight patients each. In seven of the 11 patients, 3D-CISS images showed the scolex, cystic wall, and fluid together. CONCLUSION The 3D-CISS sequence is more sensitive and specific than routine SE sequences in the diagnosis of intraventricular cysticercal cysts.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increased conspicuity of intraventricular lesions revealed by three-dimensional constructive interference in steady state sequences.

We describe our preliminary experience with the three-dimensional constructive interference in steady state (3D-CISS) sequence for the evaluation of intraventricular lesions. Cyst walls, extent and margins of tumors, and intratumoral cystic structures were clearly depicted on 3D-CISS images. The 3D-CISS sequence can offer additional information to conventional MR studies to define intraventricu...

متن کامل

The role of 3D volumetric MR sequences in diagnosing intraventricular neurocysticercosis: preliminar results.

OBJECTIVE The purpose of this paper was to investigate the role of two three-dimensional magnetic resonance (MRI) sequences: enhanced spoiled gradient recalled echo (SPGR), and fast imaging employing steady-state acquisition (FIESTA) in the evaluation of intraventricular neurocysticercosis cysts and scolices. METHOD Seven neurocysticercosis patients suspected of presenting intraventricular le...

متن کامل

Diagnosis of intraventricular cysticercosis by magnetic resonance imaging: improved detection with three-dimensional spoiled gradient recalled echo sequences.

Neurocysticercosis (NCC) is caused when the cysticercus larvae of Taenia solium infect the central nervous system. The larvae usually land in the parenchymal tissue, but quite rarely can lodge in the ventricles and cisterns of the brain. Unlike parenchymal NCC, it is not easy to demonstrate the cysticercus cysts within the cerebrospinal fluid spaces. Computed tomography and even conventional MR...

متن کامل

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

Comparing Relative Contrast in Three-dimensional Double-echo Steady State With Routine Sequences for a Better Diagnosis of Knee Cartilage Anomalies

Aims This study compared relative contrast values in three-dimensional Double Echo Steady State (DESS) sequences with two flip angles of 40 and 90 degrees and other routine sequences. The obtained data could help to prove the effects of this sequence, compared to the other routine sequences; accordingly, it could be applied for better detection of lesions resulting from cartilage abnormalities....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2000