10-year results of the uncemented Allofit press-fit cup in young patients
نویسندگان
چکیده
BACKGROUND AND PURPOSE Uncemented acetabular components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the second decade in young and active patients. We report on a minimum 10-year follow-up of an uncemented press-fit acetabular component that is still in clinical use. METHODS We examined the clinical and radiographic results of our first 121 consecutive cementless THAs using a cementless, grit-blasted, non-porous, titanium alloy press-fit cup (Allofit; Zimmer Inc., Warsaw, IN) without additional screw fixation in 116 patients. Mean age at surgery was 51 (21-60) years. Mean time of follow-up evaluation was 11 (10-12) years. RESULTS At final follow-up, 8 patients had died (8 hips), and 1 patient (1 hip) was lost to follow-up. 3 hips in 3 patients had undergone acetabular revision, 2 for deep infection and 1 for aseptic acetabular loosening. There were no impending revisions at the most recent follow-up. We did not detect periacetabular osteolysis or loosening on plain radiographs in those hips that were evaluated radiographically (n = 90; 83% of the hips available at a minimum of 10 years). Kaplan-Meier survival analysis using revision of the acetabular component for any reason (including isolated inlay revisions) as endpoint estimated the 11-year survival rate at 98% (95% CI: 92-99). INTERPRETATION Uncemented acetabular fixation using the Allofit press-fit cup without additional screws was excellent into early in the second decade in this young and active patient cohort. The rate of complications related to the liner and to osteolysis was low.
منابع مشابه
The optimal timing of baseline radiostereometric analysis of uncemented press fit cups.
BACKGROUND AND AIMS The baseline radiostereometric analysis (RSA) is usually performed during the first postoperative week. We investigated the micromotion of two uncemented press fit acetabular cups during the first week after total hip arthroplasty. MATERIAL AND METHODS All study patients had unilateral osteoarthritis of the hip and received an uncemented THA combination consisting of a CLS...
متن کاملPolyethylene wear in uncemented acetabular components.
We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated wi...
متن کاملExcellent long-term survival of an uncemented press-fit stem and screw cup in young patients: follow-up of 75 hips for 15-18 years.
BACKGROUND The long-term results of uncemented total hip arthroplasties vary widely due to differences in design, metal alloy, coating, surface structure, and porosity. PATIENTS AND METHODS We retrospectively studied 75 cementless Zweymuller SL stems in combination with Endler titanium-backed threaded cups (Z-E) in 70 patients. 35 patients were women, and the mean age at surgery was 52 (24-68...
متن کاملA cemented cup with acetabular impaction bone grafting is more cost-effective than an uncemented cup in patients under 50 years.
PURPOSE Acetabular deficiencies in young patients can be restored in several ways during total hip arthroplasty. Currently, cementless cups are most frequently used. Impaction bone grafting of acetabular defects is a more biological approach, but is it cost-effective in young patients on the long term? METHODS We designed a decision model for a cost-utility analysis of a cemented cup with ace...
متن کاملUnsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis.
A high incidence of acetabular osteolysis (43%), associated with osteolytic lesions in the proximal femur (22.6%) and leading to a high revision rate, was experienced with the Omnifit total hip prosthesis. We reviewed the clinical and radiological results with 429 Omnifit total hips in 356 patients after a mean follow-up of 60 months. Time to revision and wear of the polyethylene liner with dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 85 شماره
صفحات -