The titanium elastic nail serves as an alternative treatment for adult proximal radial shaft fractures: a cohort study

نویسندگان

  • Ying-Cheng Huang
  • Jenn-Huei Renn
  • Yih-Wen Tarng
چکیده

BACKGROUND To investigate whether closed reduction and internal fixation (CRIF) with titanium elastic nails (TENs) is a viable alternative treatment in proximal radial fractures. METHODS In Kaohsiung Veterans General Hospital, from November 2013 to April 2015, five adult male patients with forearm injuries (average age 43 years; range 35-64 years) were treated for proximal radial shaft fractures. CRIF with TENs for radial shaft fractures was performed in these five patients. Radiographs; range of motions; visual analog scale (VAS); quick disabilities of the arm, shoulder, and hand (Quick DASH) questionnaire; and time to union were evaluated in our study. RESULTS Mean follow-up period was 30 months (range 28-36 months). Average time of radius union was 7.3 months (range 6-10 months). Functional outcomes 1 year after operation revealed an average Quick DASH score of 7.92 (range 4.5-25), an average VAS of 1.5 (range 1-3), and average forearm supination and pronation of 69.2° (range 45°-75°) and 82.5° (range 80°-85°). No major complication was noted. CONCLUSIONS CRIF with TEN for adult proximal radial fractures is a method to avoid extensive exposure or nerve injury during ORIF, especially in multiple trauma patients who require short operative time, uremia patients with ipsilateral forearm AV shunt, severe soft tissue swelling due to direct muscle contusion or strong muscularity before surgery, extensive radial fracture, and those in pursuit of cosmetic outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elastic Stable Intramedullary Nailing of Femoral Shaft Fracture-Experience in 48 Children

Background: Femoral shaft fractures are an incapacitating pediatric injury accounting for 1.6% of all pediatric bonyinjuries. Management of these fractures is largely directed by age, fracture pattern, associated injuries, built of the childand socioeconomic status of the family. We retrospectively evaluated the use of elastic stable intramedullary nail (ESIN)in surgical management of femoral s...

متن کامل

Titanium Elastic Nail - Complications in the Treatment of Paediatric Diaphyseal Fracture of Femur§

BACKGROUND Femoral shaft fracture is the most common major paediatric orthopaedic. For generations traction and casting was the standard treatment for all femoral shaft fractures in children. Over the past two decades the advantages of fixation and rapid mobilisation have been increasingly recognised. METHODS A prospective study was conducted in five private hospitals in the district of Banku...

متن کامل

Treatment Outcome of Intramedullary Fixation with a Locked Rigid Nail in Humeral Shaft Fractures

  Background: The aim of this study was to determine the treatment outcome of humeral shaft fractures with a locked rigid intramedullary nail in patients indicated for surgical treatment. Methods: In this descriptive-cross sectional study, all patients were followed up for one, six, and 18 months post operatively. The Short Form Questionnaire (SF-36) and Constant Shoulder Score were applied. Re...

متن کامل

Use of Titanium Elastic Nails in the Adult Diaphyseal Humerus Fractures

Introduction: Humerus shaft fractures in adults can be managed conservatively with functional braces or operatively with plate osteosynthesis or with intramedullary nailing. Conventionally humerus intramedullary nailing is done either using humerus interlocking nails or Enders nails. In this study we analyse the outcome of humerus shaft fractures (upper and middle third) managed with closed ant...

متن کامل

Treatment of pediatric femoral shaft fractures by stainless steel and titanium elastic nail system: A randomized comparative trial

PURPOSE Literature suggests that the lower modulus of elasticity of titanium makes it ideal for use in children compared with stainless steel. Better fracture stability was observed in association with titanium nails on torsional and axial compression testing. However, stainless steel nails are stiffer than titanium counterparts, which may provide a rigid construct when fixing paediatric femora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018