Standardized comparison of processing capacity and efficiency of five new-generation immunoassay analyzers.

نویسندگان

  • H A Hendriks
  • W Kortlandt
  • W M Verweij
چکیده

BACKGROUND With the trend toward laboratory and workstation consolidation, more studies are necessary to evaluate instrumentation, solutions for coping with workflow and test diversity, and opportunities for increasing the overall efficiency of laboratory testing. We assessed the processing capacity and efficiency of new-generation immunoassay analyzers by determining productivity parameters of five commercially available systems. METHODS A workload protocol was developed and used to assess processing capacity and efficiency parameters of five immunoassay analyzers under standardized conditions in a real-life routine situation. We studied the ACS:Centaur((R)) (analyzer A), Architect(TM) i2000 (analyzer B), Elecsys((R)) 2010 tandem (analyzer C), Immulite((R)) 2000 (analyzer D), and Vitros ECi (analyzer E) on the basis of a standardized workload protocol that reflected a routine laboratory situation. This workload encompassed reflex and STAT testing, dilutions, and in-run calibration of a new reagent lot number. The analyzers were compared for hands-on labor time, unattended time (UT), throughput, and differentiated relative productivity indexes [RPI((UT)); number of reportable results/(processing time - sum of unattended time)]. The RPI data for analyzers linked to an automated (aut) sample-handling system [RPI((aut))] were also calculated. RESULTS The evaluation produced a set of parameters for the productivity of the instruments. An overview of the most important parameters revealed the following: the throughput was 193, 123, 97, 109, and 46 tests/hour for instruments A, B, C, D and E, respectively; the RPI((10)) was 425, 238, 161, 445, and 151 tests/operator-hour; the RPI((30)) was 229, 136, 118, 264, and 86 tests/operator-hour; the RPI((10,aut)) was 1701, 637, 235, 964, and 223 tests/operator-hour; and the RPI((30, aut)) was 298, 150, 174, 400, and 114 tests/operator-hour. CONCLUSIONS The combination of a standardized workload protocol and determination of parameters for productivity and labor efficiency, especially the differentiated RPIs, made it possible to make an objective comparison of the organizational consequences of the use of these instruments. The described parameters allow for a scientifically based choice, given a certain workflow and a particular laboratory organization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capacity and efficiency testing of new immunoassay analyzers.

To the Editor: We read with interest the recent report by Hendriks et al. (1 ) comparing processing capacity and efficiency for five different immunoassay analyzers. As the authors correctly state, the great diversity in laboratory organization and function means that no two laboratories have exactly the same requirements of an immunoassay analyzer. Given this reality, we would like to comment ...

متن کامل

First-trimester Combined Screening for Trisomies 21, 18, and 13 by Three Closed Chemiluminescence Immunoassay Analyzers (an Experiment on Iranian Pregnant Women)

Background: Pregnancy-associated plasma protein-A (PAPP-A) and free β-human chorionic gonadotropin (free β-hCG) as valuable biochemical biomarkers are used to screen down syndrome, Edwards syndrome, and Patau syndrome in the first trimester of pregnancy. Closed immunoassay analyzers are regarded as sophisticated platforms to measure biochemical biomarkers. This study compared the performance of...

متن کامل

Role of smile correction in mineral detection on hyperion data

This work aims to extract the mineralogical constituents of the Lahroud Hyperion scene situated in the NW of Iran. Like the other push-broom sensors, Hyperion images suffer from spectral distortions, namely the smile effect. The corresponding spectral curvature is defined as an across-track wavelength shift from the nominal central wavelength, and alters the pixel spectra. The common “column me...

متن کامل

Evaluation of a new valproic acid enzyme immunoassay and comparison with a capillary gas-chromatographic method.

A new homogeneous immunoassay (EMIT) for valproic acid was evaluated. Besides testing the manual version of this enzyme immunoassay, we also developed two mechanized procedures for centrifugal analyzers (the CentrifiChem and the COBAS system), which take less time and are more precise than the manual method. Within-assay precision (CV) was 4.5% with the manual technique and 2% with the analyzer...

متن کامل

Energy and economic comparison of SOFC-GT, MCFC-GT, and SOFC-MCFC-GT hybrid systems

Conversion of fossil fuels to electrical power is the most popular method of electrical power generation. Due to the depletion of fossil fuels and the increase in air pollution, the necessity of using high efficiency power generation systems is increasing. High temperature fuel cells, such as solid oxide fuel cells (SOFC) and molten carbonate fuel cells (MCFC), have high efficiency. According t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2000