Development of a Modelling to Correlate Site and Diameter of Brain Metastases with Hippocampal Sparing Using Volumetric Modulated Arc Therapy

نویسندگان

  • Silvia Chiesa
  • Mario Balducci
  • Luigi Azario
  • Simona Gaudino
  • Francesco Cellini
  • Gian Carlo Mattiucci
  • Cesare Colosimo
  • Vincenzo Valentini
چکیده

PURPOSE To correlate site and diameter of brain metastases with hippocampal sparing in patients treated by RapidArc (RA) technique on whole brain with simultaneously integrated boost (SIB). METHODS AND MATERIALS An RA plan was calculated for brain metastases of 1-2-3 cm of diameter. The whole brain dose was 32.25 Gy (15 fractions), and SIB doses to brain metastases were 63 Gy (2 and 3 cm) or 70.8 Gy (1 cm). Plans were optimized and evaluated for conformity, target coverage, prescription isodose to target volume, homogeneity index, and hippocampal sparing. RESULTS Fifteen brain lesions and RA plan were generated. Hippocampal volume was 4.09 cm³, and hippocampal avoidance volume was 17.50 cm³. Related to site of metastases, the mean hippocampal dose was 9.68 Gy² for occipital lobe, 10.56 Gy² for frontal lobe, 10.56 Gy² for parietal lobe, 10.94 Gy² for deep brain structures, and 40.44 Gy² for temporal lobe. The mean hippocampal dose was 9.45 Gy², 10.15 Gy², and 11.70 Gy² for diameter's metastases of 1.2 and 3 cm, respectively, excluding results relative to temporal brain lesions. CONCLUSIONS Location more than size of metastases can adversely influence the hippocampus sparing. Further investigation is necessary to meet definitive considerations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

متن کامل

Conventional radiation therapy for brain metastases

Conventional radiotherapy in the form of whole brain radiation treatment has been a longstanding treatment for brain metastases, and it continues to provide effective palliation as monotherapy and in combination with local and systemic treatments. Advances in systemic therapy have improved survival with metastatic disease, and in those patients with better prognostic factors, more aggressive lo...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Whole Brain Hippocampal Sparing Treatment Plans Based on Radiobiological Modeling

Introduction In this article, we report the results of our investigation on comparison of radiobiological aspects of treatment plans with linear accelerator-based intensity-modulated radiation therapy and volumetric-modulated arc therapy for patients having hippocampal avoidance whole-brain radiation therapy. Materials and Methods In this retrospective study using the dose-volume histogram, w...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Hippocampal sparing radiotherapy for glioblastoma patients: a planning study using volumetric modulated arc therapy

BACKGROUND The purpose of this study is to investigate the potential to reduce exposure of the contralateral hippocampus in radiotherapy for glioblastoma using volumetric modulated arc therapy (VMAT). METHODS Datasets of 27 patients who had received 3D conformal radiotherapy (3D-CRT) for glioblastoma with a prescribed dose of 60Gy in fractions of 2Gy were included in this planning study. VMAT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013