Resolution adapted finite element modeling of radio frequency interactions on conductive resonant structures in MRI.

نویسندگان

  • Jürgen Ruoff
  • Christian Würslin
  • Hansjörg Graf
  • Fritz Schick
چکیده

Prediction of interactions between the radiofrequency electromagnetic field in magnetic resonance scanners and electrically conductive material surrounded by tissue plays an increasing role for magnetic resonance safety. Testing of conductive implants or instruments is usually performed by standardized experimental setups and temperature measurements at distinct geometrical points, which cannot always reflect worst-case situations. A finite element method based on Matlab (The Mathworks, Natick, MA) and the finite element method program Comsol Multiphysics (Stockholm, Sweden) with a spatially highly variable mesh size solving Maxwell's full-wave equations was applied for a comprehensive simulation of the complete geometrical arrangement of typical birdcage radiofrequency coils loaded with small conductive structures in a homogenous medium. Conductive implants like rods of variable length and closed and open ring structures, partly exhibiting electromagnetic resonance behavior, were modeled and evaluated regarding the distribution of the B(1)- and E-field, induced currents and specific absorption rates. Numerical simulations corresponded well with experiments using a spin-echo sequence for visualization of marked B(1)-field inhomogeneities. Even resonance effects in conductive rods and open rings with suitable geometry were depicted accurately. The proposed method has high potential for complementation or even replacement of common experimental magnetic resonance compatibility measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

Experimental Study of Masonry Structure Under Impact Loading and Comparing it with Numerical Modeling Results via Finite Element Model Updating

Given the sophisticated nature of the blast phenomenon in relation to structures, it is of significance to accurately investigate the structure behavior under blast loads. Due to its rapid and transient nature, blast loading is one of the most important dynamic loadings on the structures. Since masonry materials are widely used as the partition and bearing walls in the existing and newly-built ...

متن کامل

An Investigation into Resonant Frequency of Triangular V-Shaped Cantilever Piezoelectric Vibration Energy Harvester

Power supply is a bottle-neck problem of wireless micro-sensors, especially where the replacement of batteries is impossible or inconvenient. Now piezoelectric material is being used to harvest vibration energy for self-powered sensors. However, the geometry of a piezoelectric cantilever beam will greatly affect its vibration energy harvesting ability. This paper deduces a remarkably precise an...

متن کامل

Reprint: Finite Element Modeling of Vibration Stress Relief after Welding

A finite element model was developed to simulate the vibratory stress relief after welding. Both resonant and nonresonant vibrations can relieve residual stresses in welded structures by creating plastic deformation around the weld area. For the non-resonant vibration, the stress reduction strongly depends on the vibration amplitude. For the resonant vibration, the vibration frequency is the ke...

متن کامل

Microstrip Patch Sensor for Salinity Determination

In this paper, a compact microstrip feed inset patch sensor is proposed for measuring the salinities in seawater. The working principle of the proposed sensor depends on the fact that different salinities in liquid have different relative permittivities and cause different resonance frequencies. The proposed sensor can obtain better sensitivity to salinity changes than common sensors using cond...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 67 5  شماره 

صفحات  -

تاریخ انتشار 2012