The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
نویسندگان
چکیده
BACKGROUND Small endotracheal tubes (ETTs) and neonatal ventilators can impact gas exchange, work of breathing, and lung-mechanics measurements in infants, by increasing the expiratory resistance (R(E)) to gas flow. METHODS We tested two each of the Babylog 8000plus, Avea, Carestation, and Servo-i ventilators. In the first phase of the study we evaluated (1) the imposed R(E) of an ETT and ventilator system during simulated passive breathing at various tidal volume (V(T)), positive end-expiratory pressure (PEEP), and frequency settings, and (2) the intrinsic PEEP at various ventilator settings. In the second phase of this study we evaluated the imposed expiratory work of breathing (WOB) of the ETT and ventilator system at various PEEP levels during simulated spontaneous breathing using an infant lung model. Pressure and flow were measured continuously, and we calculated the imposed R(E) of the ETT and each ventilator, and the intrinsic PEEP with various PEEP, V(T), and frequency settings. We measured the imposed expiratory WOB with several PEEP levels during a simulated spontaneous breathing pattern. RESULTS The ventilator's contribution to the imposed R(E) was greater than that of the ETT with nearly all of the ventilators tested. There were significant differences in ventilator-imposed R(E) between the ventilator brands at various PEEP, V(T), and frequency settings. The Babylog 8000plus consistently had the lowest ventilator-imposed R(E) in the majority of the test conditions. There was no intrinsic PEEP (>1 cm H(2)O) in any of the test conditions with any ventilator brand. There were also no significant differences in the imposed expiratory WOB between ventilator brands during simulated spontaneous breathing. CONCLUSIONS The major cause of R(E) appears to be the ventilator exhalation valve. Neonatal ventilators that use a set constant flow during inhalation and exhalation appear to have less R(E) than ventilators that use a variable bias flow during exhalation. Clinical studies are needed to determine whether the imposed R(E) of these ventilator designs impacts gas exchange, lung mechanics, or ventilator weaning.
منابع مشابه
Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation.
BACKGROUND The resistance of the endotracheal tube (ETT), the heat and moisture exchanger (HME), and the ventilator may affect the patient's respiratory status. Although previous studies examined the inspiratory work of breathing (WOB), investigation of WOB in the expiratory phase is rare. We estimated tracheal pressure at the tip of the ETT (Ptrach) and calculated expiratory WOB imposed by the...
متن کاملEquipment review: Mechanical effects of heat-moisture exchangers in ventilated patients
Although they represent a valuable alternative to heated humidifiers, artificial noses have unfavourable mechanical effects. Most important of these is the increase in dead space, with consequent increase in the ventilation requirement. Also, artificial noses increase the inspiratory and expiratory resistance of the apparatus, and may mildly increase intrinsic positive end-expiratory pressure. ...
متن کاملIt's Time to Reappraise the Impact of Auto-PEEP.
Since Pepe and Marini1 first used the term auto-PEEP in 1982, many studies have been conducted in this field.2-5 For patients receiving mechanical ventilation, auto-PEEP is a common problem during the weaning process.2-4 Even in the acute stage of acute respiratory failure, patients may suffer from the detrimental effects of auto-PEEP.4,5 By definition, auto-PEEP occurs when air flow does not r...
متن کاملThe Evaluation of Serum Procalcitonin Levels in Neonatal Infections
Background Procalcitonin is known as one of the bacteremia and sepsis markers such as cytokines, interleukin and reactive proteins. This study was conducted to determine the procalcitonin levels in neonatal sepsis. Materials and Methods In a cross-sectional study, the serum procalcitonin levels in 50 term newborns with suspected sepsis was compared with 50 healthy newborns in Ghaem Hospital, Ma...
متن کاملExpiratory valves used for home devices: experimental and clinical comparison.
A bench study followed by a clinical trial were performed to evaluate the mechanical characteristics of five (commercially available) expiratory valves used for home ventilators, as well as the potential clinical impact of differences between these valves. In the in vitro study, expiratory valve resistance was evaluated under unvarying conditions, whereas dynamic behaviour was evaluated by calc...