Comparative study of the transcatheter and transthoracic device closure treatments for atrial septal defect
نویسندگان
چکیده
The purpose of this study was to compare patient populations, safety, feasibility, complications, and total costs of the transcatheter and transthoracic device closure treatments for secundum atrial septal defect.From January 2014 to December 2014, we enrolled 155 patients with secundum atrial septal defects in our hospital. The patients were divided into 2 groups: the 70 patients in group A underwent transcatheter device closure, and the 85 patients in group B underwent transthoracic intraoperative device closure with a right lateral mini-thoracotomy.In group A, the total occlusion rate was 94.3% immediately after the operation, 100% at 3 months, and 100% at 12 months of follow-up; the group A results were not statistically different from the group B results (94.1%, 98.8%, 98.8%, respectively). There was a statistically significant difference in the minor complication rate (P < 0.05), and there were no reported deaths. There was a greater indicated scope using the transthoracic closure device to treat atrial septal defects. In our comparative study, the patients in group B had longer intensive care unit stays and hospital stays than group A (P < 0.05).Both of the device closure treatment options for secundum atrial septal defect are safe and feasible. The transcatheter device closure approach has the advantages of more cosmetic results, less trauma, and a shorter hospital stay than the transthoracic approach. On the contrary, the transthoracic closure device is an economical alternative choice, particularly for patients who are not eligible for the transcatheter closure device.
منابع مشابه
Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملTranscatheter closure of atrial septal defects with transthoracic echocardiography.
OBJECTIVES The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia. METHODS Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter meas...
متن کاملUrgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series
Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...
متن کاملMeasurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method
BACKGROUND Transcatheter closure of atrial septal defect secundum (ASD-II) has become an alternative method for surgery. We sought to compare the two-dimensional transesophageal echocardiography (TEE) method for measuring atrial septal defect with balloon occlusive diameter (BOD) in transcatheter ASD-II closure. METHODS A total of 39 patients (71.1% female, mean age: 35.31 ± 15.37 years) who ...
متن کاملFeasibility and Safety of Transthoracic Echocardiography-Guided Transcatheter Closure of Atrial Septal Defects with Deficient Superior-Anterior Rims
Although previous studies showed that transthoracic echocardiography (TTE) can be used to guide transcatheter closure of atrial septal defect (ASD), whether TTE can be used to guide transcatheter closure of secundum ASD with a deficient superior-anterior rim is unknown and this critical issue was addressed in the present study. A total of 280 patients with secundum ASD who underwent transcathet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 96 شماره
صفحات -
تاریخ انتشار 2017