Five-year clinical outcomes of drug-eluting stents according to on-label and off-label use
نویسندگان
چکیده
BACKGROUND/AIMS To compare the clinical outcomes of 'on-label' and 'off-label' drug-eluting stents (DESs) over a 5-year follow-up period. METHODS A total of 929 patients that underwent percutaneous coronary intervention with DESs were enrolled. Patients were divided into two groups according to on-label (n = 449) and off-label (n = 480) indications. Off-label use was defined as implantation of DESs for acute myocardial infarction (MI), very small vessel, a long stenotic lesion, chronic total occlusion, a bifurcation lesion, an ostial lesion, left main coronary artery disease, multivessel disease, a saphenous vein graft lesion, and a lesion with thrombus. Endpoints were composite of major adverse cardiac events (MACEs), which included all-cause death, ischemic-driven target vessel revascularization (Id-TVR), MI, and stent thrombosis (ST). Clinical outcomes in the two groups were compared for up to 5 years postimplantation. RESULTS At 1 year postimplantation, the off-label group had higher incidences of total MACEs (8.2% vs. 3.7%, p = 0.005), Id-TVR (5.0% vs. 1.6%, p = 0.004), and ST (1.7% vs. 0.3%, p = 0.042), and at 5 years postimplantation, the off-label group continued to have higher incidences of total MACEs (17.5% vs. 9.4%, p < 0.001), Id-TVR (13.1% vs. 5.8%, p = 0.024), and ST (2.1% vs. 0.3%, p = 0.021). Multivessel disease and diabetes were found to be independent risk factors of MACE in patients with an off-label indication. CONCLUSIONS Patients treated with an on-label DES had better long-term clinical outcomes than those treated with an off-label DES.
منابع مشابه
A comparison of bare-metal and drug-eluting stents for off-label indications.
BACKGROUND Recent reports suggest that off-label use of drug-eluting stents is associated with an increased incidence of adverse events. Whether the use of bare-metal stents would yield different results is unknown. METHODS We analyzed data from 6551 patients in the National Heart, Lung, and Blood Institute Dynamic Registry according to whether they were treated with drug-eluting stents or ba...
متن کاملOutcomes and complications with off-label use of drug-eluting stents: results from the STENT (Strategic Transcatheter Evaluation of New Therapies) group.
OBJECTIVES This study evaluates outcomes and complications in patients treated with drug-eluting stents (DES) for "off-label" indications. BACKGROUND Drug-eluting stents have been effective in randomized trials, but their safety and efficacy for off-label indications has not been well studied. METHODS The STENT (Strategic Transcatheter Evaluation of New Therapies) Registry is the largest mu...
متن کاملImmunosuppressive therapy and tolerance of organ allografts.
Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-23. Stone GW, Ellis SG, Cox DA, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221-31. Pfisterer M, Brunner-La Rocca HP, Buser PT, et al. Late clinical events after ...
متن کاملOutcomes and complications associated with off-label and untested use of drug-eluting stents.
CONTEXT Limited data exist regarding use of drug-eluting stents outside of approved indications in real-world settings. OBJECTIVES To determine the frequency, safety, and effectiveness of drug-eluting stents for off-label (restenosis, bypass graft lesion, long lesions, vessel size outside of information for use recommendation) and untested (left main, ostial, bifurcation, or total occlusion l...
متن کاملWorsening Clinical Outcome with Increasing Number of So-Called Off-Label or Unapproved Indications for Use of Drug Eluting Stents
Objective: We explored the impact of increasing number of off-label patient and lesion characteristics on 5-year clinical outcome following implantation of first generation drug eluting stents. Furthermore we tried to assess if stent performance might be improved if the off-label characteristics present were taken into account to guide the stent brand selection. Design: A total of 2888 coronary...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 31 شماره
صفحات -
تاریخ انتشار 2016