Behaviour of eccentric loading of FRP confined fibre steel reinforced concrete columns

نویسندگان

  • Muhammad N. S Hadi
  • Muhammad N. S. Hadi
چکیده

This paper presents results of testing 16 specimens, 12 of which as columns under different eccentricities and four as beams under four point loading regime. All 16 specimens were circular in cross section and were made of reinforced concrete. Four specimens served as reference specimens and were just made of reinforced concrete. The next four specimens were wrapped with Carbon Fibre Reinforced Polymers (CFRP). The next four specimens had steel fibres added to the concrete. The final four specimens were reinforced with steel fibres and wrapped with CFRP. From each group of specimens, one specimen was tested as a column under a concentric load, the second specimen was tested as a column under 25 mm eccentricity, the third specimen was tested as a column under 50 mm eccentricity, and the final specimen was tested as a beam under four point loading regime. For each group of specimens, axial force-bending moment interaction diagrams were drawn based on the experimental results and compared with theoretical estimation. The experimental programme proved that the introduction of fibres as well as wrapping the specimens with FRP improve the properties of concrete, especially its ductility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Behavior of FRP-Confined Reactive Powder Concrete Columns under Eccentric Loading

Fiber reinforced Polymers (FRP) have widely used for the purposes of enhances strength and ductility of concrete columns. Proper design of such hybrid columns, however, requires a better recognition of the behavior of concrete columns confined with FRP. In this paper, the influence of FRP thickness, concrete compressive strength, and column size on the performance of eccentrically loaded reacti...

متن کامل

Numerical and Experimental Investigations on the Behavior of Steel-reinforced Concrete Columns Subjected to Eccentric Loading

Steel-reinforced concrete (SRC) columns, which are classified as composite columns, became the most widely used in recent years; because of their extensive advantages over the reinforced concrete and the steel columns. In this paper, the ductility index and its influential factors were explored to investigate the behavior of SRC columns. A straightforward approach was then proposed by establish...

متن کامل

Behaviors of Concrete Columns Confined with Both Spiral and Fiber Composites

Concrete columns confined with high-strength fiber reinforced polymer (FRP) composites can enhance the strength as well as the ductility of such structures. In recent years, the use of FRP composites to repair and strengthen existing reinforced concrete (RC) structures has been widely used. When the columns of existing RC structures are wrapped with FRP composites, the core concrete of such col...

متن کامل

The behaviour of FRP wrapped HSC columns under different eccentric loads

The majority of columns are subjected to a combination of an axial load and a bending moment in one or two directions. With a few exceptions, most of the research in the area of FRP wrapped columns have concentrated on the behaviour of concentrically loaded columns. This paper presents results of testing nine reinforced high strength concrete columns. The column specimens are circular in shape ...

متن کامل

Workshop Presentation Infrastructure Applications of Frp Composites Behaviour of High Strength Concrete Columns Reinforced with Gfrp Bars and Helices under Different Loading Conditions

The use of Glass Fibre Reinforced Polymer (GFRP) bars is considered an alternative option in reinforcing concrete structures instead of conventional steel bars especially in harsh severe environments, due to their mechanical properties and physical characteristics. GFRP bars offer many advantages over steel counterparts such as corrosion resistance, high tensile strength, low weight and electro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016