MRI Pulse Sequences
نویسنده
چکیده
Saturation Recovery The simplest sequence is known as Saturation Recovery in which there is a single 90? pulse and a long repetition time between pulses. If the signal is measured immediately following the pulse the image will depend on the proton density. If the sequence is repeated rapidly (short repetition time, TR) there will be only partial relaxation and the results will depend on proton density and T1. Such a sequence is known as Partial Saturation Recovery.
منابع مشابه
The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...
متن کاملI-42: MRI Evaluation of Congenital Uterine Anomalies
Mullerian duct anomalies are an uncommon but often treatable cause of infertility. Patients with müllerian duct anomalies are known to have a higher incidence of infertility, repeated first-trimester spontaneous abortions, fetal intrauterine growth retardation, fetal malposition, preterm labor, and retained placenta. The role of imaging is to help detect, diagnose, and distinguish surgically co...
متن کاملNon-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...
متن کاملA high performance parallelizable MRI physics simulator with graphic processing unit technology
Background The acquisition of high quality Magnetic Resonance (MR) images requires exploring a parameter space for image quality improvement. This iterative process can benefit from simulations of MRI pulse sequences and imaging protocols. Current MRI physics simulators are confined to few pulse sequences and compromises are made due to the high computational power needed. A step-by-step compre...
متن کاملI-45: Advance MRI Sequences in Pelvic Endometriosis
Background: To assess MRI in diagnosing endometriotic lesions, emphasizing T2*weighted imaging efficacy. Materials and Methods: This prospective study of 48 females (22-38 years, average 29.6) clinically suspected of endometriosis from September 2009 to April 2012. MRI was performed with a 1.5 T imager (Siemens) with a body array coil. T1, T2 and T2* weighted (2D-FLASH) sequences were obtained ...
متن کاملMRI of the lung (1/3): methods
Proton magnetic resonance imaging (MRI) has recently emerged as a clinical tool to image the lungs. This paper outlines the current technical aspects of MRI pulse sequences, radiofrequency (RF) coils and MRI system requirements needed for imaging the pulmonary parenchyma and vasculature. Lung MRI techniques are presented as a "technical toolkit", from which MR protocols will be composed in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 103 شماره
صفحات -
تاریخ انتشار 1988