Effect of iterative reconstruction on image quality of low-dose chest computed tomography.
نویسندگان
چکیده
AIM To assess quality and radiologists' preference of low-dose computed tomography (LDCT) reconstructed with filtered back projection (FBP) or Iterative Reconstruction. METHODS Thin-section LDCTs (1-mm thick contiguous images; 120 kVp; 30 mAs) of 38 consecutive unselected patients, evaluated for various clinical indications, were reconstructed by four different reconstruction algorithms: FBP and Sinogram-AFfirmed Iterative Reconstruction (SAFIRE) with three different strengths, from 2 to 4 (i.e. S2, S3, S4). The image noise was recorded. Two thoracic radiologists visually compared both anatomic structures (interlobular septa, lung fissures, centrilobular artery, bronchial wall, and small vessels) and lung abnormalities (intralobular reticular opacities, nodules, emphysema, cystic lung disease, decreased-attenuation areas related to constrictive obliterans bronchiolitis, patchy ground-glass opacity, consolidation, and bronchiectasis) using a qualitative four-point scale grading system of the image quality. RESULTS A lower amount of noise was recorded for LDCTs reformatted with any SAFIRE algorithm, as compared to FBP (P < 0.0001). The noise levels decreased as the SAFIRE strength increased from S2 to S4. The visual score of the subsegmental/segmental bronchial wall was greater for the FBP datasets compared to any SAFIRE dataset (P < 0.0001 for reviewer 1; P < 0.02 for reviewer 2). The decreased lung attenuation pattern score was lower on the S4 images for one reviewer, as compared to the other LDCT datasets (P = 0.003). No other differences in terms of radiologists' preference were recorded among FBP, S2, S3, and S4. Interobserver agreement was moderate only for fissures and bronchial wall, and good to excellent for the remainders. CONCLUSION Iterative reconstructions showed lower image noise but did not provide any real improvement for the radiologists' evaluation of thin-section LDCT of the lung.
منابع مشابه
Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملDose Reduction Methods in Chest Computed Tomography
Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملApplication of Different methods for Reducing Radiation Dose to Breast during MDCT
The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...
متن کاملReduced-dose low-voltage chest CT angiography with Sinogram-affirmed iterative reconstruction versus standard-dose filtered back projection.
PURPOSE To evaluate image quality of low-voltage chest computed tomographic (CT) angiography with raw data-based iterative reconstruction (sonogram-affirmed iterative reconstruction) in comparison with image quality of standard-dose standard-voltage filtered back projection (FBP) CT. MATERIALS AND METHODS This prospective study was approved by the institutional review board, and the informed ...