Sensitivity analysis of a CCD-based camera system for the retrieval of bidirectional reflectance distribution function for vicarious calibration
نویسندگان
چکیده
The University of Arizona, Optical Sciences Center, Remote Sensing Group is involved with the vicarious calibration of satellite sensors in support of NASA’s Earth Observing System (EOS) program. Sensor calibration coefficients are calculated by comparing sensor DN values to top of the atmosphere (TOA) radiance values, calculated from radiative transfer code (RTC). The RTC output is based on measurements of site spectral reflectance and atmospheric parameters at a selected test site. The bidirectional reflectance distribution function (BRDF) which relates the angular scattering of a given beam of incident radiation on a surface, is an important factor in these radiative transfer calculations. The inclusion of BRDF data into RTC calculations improves the level of accuracy of the vicarious calibration method by up to 5% over some target sites. BRDF data is also valuable in the validation of Multi-Angle Imaging Spectroradiometer (MISR) data sets. The Remote Sensing Group has developed an imaging radiometer system for ground-based measurements of BRDF. This system relies on a commercially-available 1024by 1024-pixel silicon CCD array. Angular measurements are accomplished with a 8-mm focal length fisheye lens that has a full 180-degree field of view. Spectral selection is through four interference filters centered at 470, 575, 660 and 835 nm, mounted internally in the fisheye lens. This paper discusses the effect of calibration errors in this camera system on the retrieval of Hapke/Jacquemoud surface parameters from modeled BRDFs. The effect of these retrieved BRDFs on vicarious calibration results is discussed. Data processing schemes for the retrieval of these parameters from BRDF camera data sets are described. Based on these calculations, calibration requirements for digital camera BRDF-retrieval systems are presented.
منابع مشابه
Sensitivity Analysis and Error Analysis of Reflectance Based Vicarious Calibration with Estimated Aerosol Refractive Index and Size Distribution Derived from Measured Solar Direct and Diffuse Irradiance as well as Measured Surface Reflectance
Sensitivity analysis and error of reflectance based vicarious calibration with estimated aerosol refractive index and size distribution derived from measured solar direct and diffuse irradiance as well as measured surface reflectance is conducted for solar reflective channels of mission instruments onboard remote sensing satellites. Through these error analyses, it is found that the most influe...
متن کاملVicarious calibration of CCD camera on CBERS02B using Gongger test site
on September 19 2007, CBERS02B, the third land resource satellite jointly developed by China and Brazil was successfully launched with three payloads on it, one of which is CCD camera. Calibration of CCD is a precursor for its quantitative application because there wasn’t onboard calibrator for CCD. Then a comprehensive vicarious calibration and validation experiment of CCD was performed at Gon...
متن کاملUsing analytical description of snow BRDF for visible channel calibration
Vicarious calibration using different types of land surface and deep convective clouds is considered as a mode to monitor the sensor performance. Snow cover as the brightest and in many cases spatially uniform surface has a significant potential as a calibration target. Proposed in this presentation approach is based on the creation and implementation of analytical bidirectional reflectance dis...
متن کاملA Spectralon BRF data base for MISR calibration applications
The Multi-angle Imaging SpectroRadiometer (MISR) is an Earth-observing sensor, which provides global retrievals of aerosols, clouds, and land surface parameters. Instrument specifications require an accurate absolute calibration, as well as accurate camera-to-camera, band-to-band and pixel-to-pixel relative response determinations. In order to achieve these requirements, MISR makes use of an on...
متن کاملExperimental Approach of Reflectance Based Vicarious Calibration Method for Solar Reflectance Wavelength Region of Sensor Onboard Remote Sensing Satellites
Experimental approach of reflectance based vicarious calibration of solar reflectance wavelength region of mission instruments onboard remote sensing satellites is conducted. As an example, vicarious calibration of ASTER/VNIR with estimated aerosol refractive index and size distribution that depends on atmospheric conditions is discussed. Strange solution of estimated refractive index and size ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003