Accurate LC Peak Boundary Detection for 16O/18O Labeled LC-MS Data

نویسندگان

  • Jian Cui
  • Konstantinos Petritis
  • Tony Tegeler
  • Brianne Petritis
  • Xuepo Ma
  • Yufang Jin
  • Shou-Jiang (SJ) Gao
  • Jianqiu (Michelle) Zhang
چکیده

In liquid chromatography-mass spectrometry (LC-MS), parts of LC peaks are often corrupted by their co-eluting peptides, which results in increased quantification variance. In this paper, we propose to apply accurate LC peak boundary detection to remove the corrupted part of LC peaks. Accurate LC peak boundary detection is achieved by checking the consistency of intensity patterns within peptide elution time ranges. In addition, we remove peptides with erroneous mass assignment through model fitness check, which compares observed intensity patterns to theoretically constructed ones. The proposed algorithm can significantly improve the accuracy and precision of peptide ratio measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative proteome analysis of human plasma following in vivo lipopolysaccharide administration using 16O/18O labeling and the accurate mass and time tag approach.

Identification of novel diagnostic or therapeutic biomarkers from human blood plasma would benefit significantly from quantitative measurements of the proteome constituents over a range of physiological conditions. Herein we describe an initial demonstration of proteome-wide quantitative analysis of human plasma. The approach utilizes postdigestion trypsin-catalyzed 16O/18O peptide labeling, tw...

متن کامل

Global quantitative proteomic profiling through 18O-labeling in combination with MS/MS spectra analysis.

Several stable-isotope-based peptide labeling methods have been developed to support large-scale relative quantitation, through mass spectrometry, of proteins present in two different biological samples. In one of these, trypsin-catalyzed 18O-based labeling, quantitation is typically performed at the full scan (MS) level by comparing the peak intensities of sister precursor ions corresponding t...

متن کامل

Characterization of fast-decaying PET radiotracers solely through LC-MS/MS of constituent radioactive and carrier isotopologues

UNLABELLED BACKGROUND The characterization of fast-decaying radiotracers that are labeled with carbon-11 (t1/2 = 20.38 min), including critical measurement of specific radioactivity (activity per mole at a specific time) before release for use in positron-emission tomography (PET), has relied heavily on chromatographic plus radiometric measurements, each of which may be vulnerable to signifi...

متن کامل

Comparative cytochrome P450 proteomics in the livers of immunodeficient mice using 18O stable isotope labeling.

Quantitative changes in cytochrome P450 (CYP) proteins involved in drug metabolism as a consequence of drug treatment are important parameters in predicting the fates and pharmacological consequences of xenobiotics and drugs. In this study we undertook comparative P450 proteomics using liver from control and 1,4-bis-2-(3,5-dichloropyridyloxybenzene) (TCPOBOP)-dosed mice. The method involved sep...

متن کامل

LC-MS data analysis for differential protein expression detection.

In proteomic studies, liquid chromatography coupled with mass spectrometry (LC-MS) is a common platform to compare the abundance of various peptides that characterize particular proteins in biological samples. Each LC-MS run generates data consisting of thousands of peak intensities for peptides represented by retention time (RT) and mass-to-charge ratio (m/z) values. In label-free differential...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013