In Vitro Study of Coded Transmission in Synthetic Aperture Ultrasound Imaging Systems
نویسندگان
چکیده
In the paper the study of synthetic transmit aperture method applying the Golay coded transmission for medical ultrasound imaging is presented. Longer coded excitation allows to increase the total energy of the transmitted signal without increasing the peak pressure. Moreover signal-to-noise ratio and penetration depth are improved while maintaining high ultrasound image resolution. In the work the 128-element linear transducer array with 0.3 mm inter-element spacing excited by one cycle and the 8 and 16bit Golay coded sequences at nominal frequency 4 MHz was used. To generate a spherical wave covering the full image region a single element transmission aperture was used and all the elements received the echo signals. The comparison of 2D ultrasound images of the tissue mimicking phantom and in vitro measurements of the beef liver is presented to illustrate the benefits of the coded transmission. The results were obtained using the synthetic aperture algorithm with transmit and receive signals correction based on a single element directivity function. Keywords—Golay coded sequences, radiation pattern, signal processing, synthetic aperture, ultrasound imaging.
منابع مشابه
Coded Transmission in Synthetic Transmit Aperture Ultrasound Imaging Method
The paper presents the study of synthetic transmit aperture method applying the Golay coded transmission for medical ultrasound imaging. Longer coded excitation allows to increase the total energy of the transmitted signal without increasing the peak pressure. Signal-to-noise ratio and penetration depth are improved maintaining high ultrasound image resolution. In the work the 128-element linea...
متن کاملImproving the quality of ultrasound images using Bayesian estimators
Medical ultrasound imaging due to close behavior of cancer tumors to body tissues has a low contrast. This problem with synthetic aperture imaging method has been addressed. Although the synthetic aperture imaging technique solved the low-contrast problem of ultrasound images, to an acceptable limit, but the performance of these methods is not even acceptable when the signal to noise ratio (SNR...
متن کاملMutually Orthogonal Golay Complementary Sequences in Synthetic Aperture Imaging Systems
The main objective of this study is to improve the ultrasound image by employing a new algorithm based on transducer array element beam pattern correction implemented in the synthetic transmit aperture (STA) method combined with emission of mutually orthogonal complementary Golay sequences. Orthogonal Golay sequences can be transmitted and received by different transducer elements simultaneousl...
متن کاملSynthetic Transmit Aperture Method in Medical Ultrasonic Imaging
The work describes the use of a synthetic transmit aperture (STA) with a single element transmitting and all elements receiving in medical ultrasound imaging. STA technique is a novel approach to today’s commercial systems, where an image is acquired sequentially one image line at a time that puts a strict limit on the frame rate and the amount of data needed for high image quality. The STA ima...
متن کاملMicrowave Imaging Using SAR
Polarimetric Synthetic Aperture Radar (Pol.-SAR) allows us to implement the recognition and classification of radar targets. This article investigates the arrangement of scatterers by SAR data and proposes a new Look-up Table of Region (LTR). This look-up table is based on the combination of (entropy H/Anisotropy A) and (Anisotropy A/scattering mechanism α), which has not been reported up now. ...