Novel 3 D Computerized Threshold Amsler Grid Test
نویسندگان
چکیده
Purpose: To introduce a novel 3D computerized threshold Amsler grid test, developed by Fink and Sadun, that allows for a novel characterization of the structure of visual field defects in three dimensions (see http://www.wfbabcom5.com/wf335.htm). Methods: With one eye covered, patients are placed in front of a computer monitor displaying an Amsler grid. While focusing on a varying central fixation marker, the patients trace the areas, on a touch sensitive screen overlaying the displayed grid, that are missing from their field of vision, with their finger. The procedure is repeated with varying degrees of grid contrast. The results are recorded and later displayed as topographical contour rings, in a 3D depiction of the central hill-of-vision. Results: Several clinical pilot studies have been conducted at the Doheny Eye Institute and over 200 patients have been examined so far. Conditions such as optic neuritis, anterior ischemic optic neuropathy, age-related macular degeneration, glaucoma, and ocular hypertension have been examined with the 3D visual field test. The tested visual field is limited to the central 20 to 25 degrees (depending on the computer monitor size). The physiological blind spot cannot be detected with this test due to the " fill-in phenomenon ". Conclusions: The 3D computerized threshold Amsler grid test is an innovative and fast (4-5 min. per eye) visual field test. It provides several novel features, including: a) additional information through immediate 3D rather than 2D depiction of scotomas, such as location, extent, slope, depth, and shape; b) simple test-setup; c) good patient compliance. In light of results from pilot studies, the 3D visual field test appears to have the potential for the early detection and monitoring of various diseases, in particular glaucoma and macular degeneration. 3 1. Introduction Visual field testing (perimetry) has always been an important part of an ophthalmological evaluation. In 1947 Amsler [1, 2] introduced a suprathreshold grid for evaluating the central ten degrees of the visual field. The high contrast of the standard Amsler test may fail to detect subtle field defects, such as relative scotomas.
منابع مشابه
Three-dimensional computer-automated threshold Amsler grid test.
We describe a novel method for testing a visual field that employs a computer monitor with displays of varying contrast that permits unprecedented resolution and characterization of the structure of scotomas in three dimensions. Patients are placed in front of a touch-sensitive computer screen at a fixed distance. With one eye covered, they focus on a central fixation marker and trace with thei...
متن کاملScotomas of age-related macular degeneration detected and characterized by means of a novel three-dimensional computer-automated visual field test.
PURPOSE We used the recently devised three-dimensional computer-based threshold Amsler grid test to acquire and identify typical patterns of visual field defects (scotomas) caused by age-related macular degeneration (AMD). METHODS Patients with AMD traced on a computer touch screen the borders of those areas on an Amsler grid that were missing from their field of vision. Scotomas were repeate...
متن کاملDistinguishing wet from dry age-related macular degeneration using three-dimensional computer-automated threshold Amsler grid testing.
BACKGROUND/AIMS With the increased efficacy of current therapy for wet age-related macular degeneration (AMD), better ways to detect wet AMD are needed. This study was designed to test the ability of three-dimensional contrast threshold Amsler grid (3D-CTAG) testing to distinguish wet AMD from dry AMD. METHODS Conventional paper Amsler grid and 3D-CTAG tests were performed in 90 eyes: 63 with...
متن کاملThreshold Amsler grid as a screening tool for asymptomatic patients on hydroxychloroquine therapy.
BACKGROUND/AIMS Patients taking hydroxychloroquine (HCQ) are at risk of developing classic bull's eye maculopathy. Currently, the standard Amsler grid (AG) is one of the most useful methods to identify such lesions. However, AG is a suprathreshold target and may not detect relative central scotomas. The aim of this study was to determine if the threshold Amsler grid (TAG) test, which varies lig...
متن کاملNovel 3D computer-automated threshold Amsler grid visual field testing of scotomas in patients with glaucoma.
PURPOSE Three-dimensional (3D) computer-automated threshold Amsler grid testing was used to identify and characterize scotomas typical of glaucoma. METHODS The 3D test exhibits a grid on a computer screen at a preselected grayscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. Eleven eyes in patients w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004