Recent analytical methods for cephalosporins in biological fluids.

نویسندگان

  • R D Toothaker
  • D S Wright
  • L A Pachla
چکیده

Since 1980, RP chromatography has been the principal analytical technique used for cephalosporins. This technology offers selectivity, accuracy, and ease of use. Most of the methods rely on protein precipitation and, to a lesser extent, solid-phase isolation or extraction procedures. The proper selection of a method depends on the analytical constraints imposed by the overall objective of the study. For example, pharmacokinetic datum interpretation mandates that the method be validated and provide specific and accurate results. LC is the preferred technique, since it not only meets these specifications but may also distinguish between the drug and metabolites. Those chromatographic methods which quantify several different cephalosporins are not desirable for pharmacokinetic datum interpretation, since accuracy and precision are usually compromised in order that many different drugs may be quantified in a single analysis. The proper selection of sample preparation method is dependent on the presence of potential interferences and the acceptable lower limit of quantitation. Protein precipitation methods offer ease of sample preparation but may suffer from nonselectivity. Solid-phase isolation and extraction procedures may increase selectivity and improve the limit of quantitation. Although LC provides specific and accurate results, clinical laboratories may prefer to use the less specific methods for therapeutic drug monitoring. In this case, microbiological, enzymatic, and fluorimetric methods offer improved sample throughput but less specificity. However, these methods should not be used for drugs that may have a low margin of safety or if the patient is on multiple-antibiotic therapy. Future methods may involve incorporating solid-phase isolation columns to enhance the specificity of chromatographic, microbiological, enzymatic, and fluorescence methods. Advancements in microbore column technology may allow improvements in the selectivity and sensitivity of LC methods. Many investigators prefer to use simple protein precipitation procedures for sample preparation because of sample throughput constraints. However, advances in robotic sample preparation may allow the more cumbersome solid-phase isolation or extraction techniques to be used to improved sample throughput and specificity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Synthetic Phenolic Antioxidants in Biological Fluids Based on Air-assisted Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

An air–assisted liquid–liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography–flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an a...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Hplc Analysis of Cephalosporins and Study of Different Analytical Parameters

Cephalosporins are the most important type of antibiotics used vary widely. Analysis of these antibiotics is challenge because of their sensitivity and instability to different conditions. The present review is extended to find out different HPLC methods used for analysis for cephalosporins in formulations and biological fluids. The chromatographic conditions used for the analysis as well as an...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Design and Fabrication of PVC Membrane Electrode Based on Netural Ligand (E)-N'-(1-(2-Hydroxyphenyl)Ethylidene)Benzohydrazi for Teramadol hydrochloride Measurement in Drugs and Biological Fluids

Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 31 8  شماره 

صفحات  -

تاریخ انتشار 1987