Three-dimensional imaging of the human retina by high-speed optical coherence tomography.

نویسندگان

  • Christoph Hitzenberger
  • Peter Trost
  • Pak-Wai Lo
  • Qienyuan Zhou
چکیده

Conventional optical coherence tomography is based on A-scans, i.e., the fast scan direction is the z-direction. While this technique has been successfully demonstrated for two-dimensional cross sectional imaging of various tissues, it is rather slow if three-dimensional information is to be obtained. We report on a new technique that combines the transverse scanning approach of a confocal scanning laser ophthalmoscope with the depth sectioning capability of OCT. A stable high-frequency carrier is generated by use of an acousto optic modulator, and high frame rate is obtained by using a resonant scanning mirror for the priority scan (x-direction). Our prototype instrument records 64 transverse images consisting of 256x128 pixels in 1.2 seconds, thus providing the fastest retinal 3D OCT scanning system reported so far. We demonstrate the capabilities of our system by measuring and imaging the fovea and the optic nerve head region of healthy human volunteers in vivo.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.

PURPOSE To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. METHODS Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain ...

متن کامل

Experimental Visualization of Labyrinthine Structure with Optical Coherence Tomography

Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...

متن کامل

Automated 3D Reconstruction and Segmentation from Optical Coherence Tomography

Ultra-High Resolution Optical Coherence Tomography is a novel imaging technology that allows non-invasive, high speed, cellular resolution imaging of anatomical structures in the human eye, including the retina and the cornea. A three-dimensional study of the cornea, for example, requires the segmentation and mutual alignment of a large number of two-dimensional images. Such segmentation has, u...

متن کامل

Noninvasive volumetric imaging and morphometry of the rodent retina with high-speed, ultrahigh-resolution optical coherence tomography.

PURPOSE To demonstrate high-speed, ultrahigh-resolution optical coherence tomography (OCT) for noninvasive, in vivo, three-dimensional imaging of the retina in rat and mouse models. METHODS A high-speed, ultrahigh-resolution OCT system using spectral, or Fourier domain, detection has been developed for small animal retinal imaging. Imaging is performed with a contact lens and postobjective sc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 11 21  شماره 

صفحات  -

تاریخ انتشار 2003