A Clinical Predictive Model for Catheter Related Bloodstream Infections from the Electronic Medical Record

نویسندگان

  • Gonzalo M.L. Bearman
  • Michael I. Oppenheim
  • Eneida A. Mendonca
  • Nathaniel Hupert
  • Maryam Behta
  • Paul J. Christos
  • Lewis M. Drusin
چکیده

Background and Methods: Previous studies identifying risk factors for catheter related blood stream infections (BSI) have relied on labor-intensive paper chart review. The electronic medical record (EMR) can provide real-time data for profiling patients at risk for BSI. Our study’s aim was to use our hospital EMR to identify risk factors and develop a clinical predictive model for catheter related BSI from June 2001-June 2002. Using a modified CDC definition for BSI, we retrospectively extracted a number of variables from the EMR data repository including demographics, medications, nutritional status, presence of diabetes (DM), skin/wound status, use of a mechanical ventilator, and presence of a urinary catheter or central/arterial/PICC catheter. We developed a Cox Proportional Hazards model using half the cohort (14,977 controls and 123 BSI cases), and validated the model using the other half. Final variables in the multivariate model were chosen by clinical relevance, significance on univariate analysis and by step-wise automated selection. Results: The final model contained: use of antibiotics (HR 4.6), central venous catheter for 0-6 days (HR 1.8), central venous catheter for greater or equal to 7 days (HR 1.3), tunneled central venous port (HR 9.3) and DM (HR 2.1). Variables from multivariate analysis were used for the predictive index; points were derived from the respective HR of the Cox model. A cutoff value that maximized sensitivity (75%) and specificity (89%) had a positive predictive value (PPV) of .05. This model was validated on the second half of the cohort (122 BSI, 14,977 ‘non-cases’) with resultant sensitivity of 69%, specificity of 88% and PPV of 0.05. Comparison of the two models revealed no significant differences in the sensitivity, specificity and PPV. Conclusion: We successfully used a hospital-based EMR in developing a Cox Proportional Hazards model for catheter related BSI. This model was used to derive a predictive index. At a cutoff point providing a sensitivity of 75% and specificity of 89% for finding patients who develop catheter related BSI, the index had a PPV 0.05. When applied to a predictive index, real time data gathered from the EMR may assist in identifying patients at risk for a catheter related BSI and may be further utilized as part of a protocol driven, preventive strategy for catheter related BSI risk reduction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review of recommendations to prevent and reduce catheter-related bloodstream infections

ABSTRACT Aim. We sought to review studies regarding interventions to prevent or reduce catheter-related bloodstream infections (CRBSIs). Background. CRBSIs are associated with peripheral and central intravenous catheters, including nontunneled central catheters, tunneled central catheters, peripherally inserted central venous catheters (PICC), totally implanted intravascular access devices (por...

متن کامل

Use of maximal sterile barriers during central venous catheter insertion: clinical and economic outcomes.

BACKGROUND We performed a cost-effectiveness analysis to determine the effect of maximal sterile barriers (MSBs) on reducing central venous catheter (CVC)--related infections. Use of MSBs when placing CVCs may reduce the risk of infections but is more cumbersome, time-consuming, and expensive than other techniques. METHODS We developed a decision analytic model in which a patient could have a...

متن کامل

Diagnosing Catheter-Related Bloodstream Infection

To the Editor—I want to congratulate Bouza et al. [1] for their effort to solve part of the puzzle regarding the diagnosis of catheter-related bloodstream infection without catheter removal in critically ill patients [1]. I would like to make 2 comments to place the results in a broader perspective. The authors excluded arterial and Swan-Ganz catheters from the analysis, notwithstanding the fac...

متن کامل

Model formulation: Formulation of a model for automating infection surveillance: algorithmic detection of central-line associated bloodstream infection

OBJECTIVE To formulate a model for translating manual infection control surveillance methods to automated, algorithmic approaches. DESIGN We propose a model for creating electronic surveillance algorithms by translating existing manual surveillance practices into automated electronic methods. Our model suggests that three dimensions of expert knowledge be consulted: clinical, surveillance, an...

متن کامل

A Review of the Process of Meaningful Use Program and its Challenges in the Electronic Health Record Roadmap

Introduction: Meaningful use program indicates that health care organizations make meaningful use of an accredited electronic health record system. The objective of this study was to investigate the process of “meaningful use” program and the related challenges for the development of electronic health record. Method: This review study was conducted in 2020. The PubMed, Scopus, Science Direct, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010